DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID 

VALVE

EC-941

< SERVICE INFORMATION >

[VK45DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

On Board Diagnosis Logic

INFOID:0000000001326776

DTC Confirmation Procedure

INFOID:0000000001326777

NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm battery voltage is more than 11V at idle.

1.

Start engine and let it idle for at least 13 seconds.

2.

Check 1st trip DTC.

3.

If 1st trip DTC is detected, go to 

EC-943, "Diagnosis Procedure"

.

DTC No.

Trouble diagnosis name

DTC detecting condition

Possible cause

P0444
0444

EVAP canister purge volume 
control solenoid valve circuit 
open

An excessively low voltage signal is sent 
to ECM through the valve

• Harness or connectors

(The solenoid valve circuit is open or 
shorted.)

• EVAP canister purge volume control so-

lenoid valve

P0445
0445

EVAP canister purge volume 
control solenoid valve circuit 
shorted

An excessively high voltage signal is sent 
to ECM through the valve

• Harness or connectors

(The solenoid valve circuit is shorted.)

• EVAP canister purge volume control so-

lenoid valve

EC-942

< SERVICE INFORMATION >

[VK45DE]

DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID 

VALVE

Wiring Diagram

INFOID:0000000001326778

Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-III.

CAUTION:

TBWM1338E

DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID 

VALVE

EC-943

< SERVICE INFORMATION >

[VK45DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.

: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)

Diagnosis Procedure

INFOID:0000000001326779

1.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect EVAP canister purge volume control solenoid valve
(1) harness connector.

-

EVAP service port (2)

3.

Turn ignition switch ON.

TER-

MI-

NAL 

NO.

WIRE 

COLOR

ITEM

CONDITION

DATA (DC Voltage)

45

W

EVAP canister purge volume 
control solenoid valve

[Engine is running]
• Idle speed

BATTERY VOLTAGE

(11 - 14V)

[Engine is running]
• Engine speed: About 2,000 rpm (More than 

100 seconds after starting engine)

11 - 14V

111

W/B

ECM relay
(Self shut-off)

[Engine is running]
[Ignition switch: OFF]
• For a few seconds after turning ignition 

switch OFF

0 - 1.5V

[Ignition switch: OFF]
• More than a few seconds after turning igni-

tion switch OFF

BATTERY VOLTAGE
(11 - 14V)

119

120

R
R/B

Power supply for ECM

[Ignition switch: ON]

BATTERY VOLTAGE
(11 - 14V)

PBIB0050E

PBIB0051E

PBIB3238E

EC-944

< SERVICE INFORMATION >

[VK45DE]

DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID 

VALVE

4.

Check voltage between EVAP canister purge volume control
solenoid valve terminal 1 and ground with CONSULT-III or
tester.

OK or NG

OK

>> GO TO 3.

NG

>> GO TO 2.

2.

DETECT MALFUNCTIONING PART

Check the following.
• Harness connectors E211, M41
• Harness connectors M82, F102
• Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
• Harness for open or short between EVAP canister purge volume control solenoid valve and ECM

>> Repair open circuit or short to ground or short to power in harness or connectors.

3.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT

FOR OPEN AND SHORT

1.

Turn ignition switch OFF.

2.

Disconnect ECM harness connector.

3.

Check harness continuity between ECM terminal 45 and EVAP canister purge volume control solenoid
valve terminal 2. Refer to Wiring Diagram.

4.

Also check harness for short to ground and short to power.

OK or NG

OK (With CONSULT-III)>>GO TO 4.
OK (Without CONSULT-III)>>GO TO 5.
NG

>> Repair open circuit or short to ground or short to power in harness or connectors.

4.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION

 With CONSULT-III

1.

Reconnect all harness connectors disconnected.

2.

Start engine.

3.

Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-III. Check that engine speed var-
ies according to the valve opening.

OK or NG

OK

>> GO TO 6.

NG

>> GO TO 5.

5.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE

Refer to 

EC-945, "Component Inspection"

.

OK or NG

OK

>> GO TO 6.

NG

>> Replace EVAP canister purge volume control solenoid valve.

6.

CHECK INTERMITTENT INCIDENT

Refer to 

EC-717

.

>> INSPECTION END

Voltage: Battery voltage

PBIB0148E

Continuity should exist.

 

 

 

 

 

 

 

Content   ..  543  544  545  546   ..