COMBINATION METER DISPLAY FUNCTION DLK-107 < DTC/CIRCUIT DIAGNOSIS > C D E F G H I J L M A B DLK N O P COMBINATION METER DISPLAY FUNCTION Description INFOID:0000000005239612 Displays each operation method guide and warning for system malfunction. Component Function Check INFOID:0000000005239613 1. CHECK FUNCTION Check the operation with (“LCD”) in the Active Test. Is the inspection result normal? YES >> Meter display is OK. NO >> Refer to DLK-107, "Diagnosis Procedure" Diagnosis Procedure INFOID:0000000005239614 1. CHECK COMBINATION METER Is the inspection result normal? YES >> GO TO 2. NO >> Check combination meter. Refer to . 2. CHECK INTERMITTENT INCIDENT GI-36, "Intermittent Incident" . >> INSPECTION END Is each warning displayed on meter display? |