Content .. 1152 1153 1154 1155 ..
INSPECTION AND ADJUSTMENT HAC-13 < BASIC INSPECTION > [AUTOMATIC AIR CONDITIONER] C D E F G H J K L M A B HAC N O P 3. Press mode switch as desired. NOTE: WITH ACCS : Inlet Port Memory Function INFOID:0000000005246207 DESCRIPTION When ignition switch is turned from OFF to ON, inlet port can be set to AUTO or manual. Operating procedures for this trimmer are as per the following: 1. Begin self-diagnosis STEP-5 mode. Refer to HAC-62, "WITH ACCS : Diagnosis Description" . 2. Press fan (UP: +) switch to set system in auxiliary mode. 3. Press intake switch as desired. NOTE: WITH ACCS : Gas Sensor Sensitivity Adjustment Function INFOID:0000000005246208 DESCRIPTION According to customer ′ s sense of smell, gas sensor sensitivity can be changed. Operating procedures for this trimmer are as follows: 1. Begin self-diagnosis STEP-5 mode. Refer to HAC-62, "WITH ACCS : Diagnosis Description" . 2. Press fan (UP: +) switch two times to set system in auxiliary mode. 3. Turn temperature control dial (driver side) as desired for the setting. JSIIA1209GB AUTO INTAKE indicator REC indicator Setting status Setting changeover method FRE REC OFF ON AUTO control (Initial setting) Manual REC status is memorized. Intake switch: ON ON ON Manual FRE status is memorized. Manual REC status is memorized. ON OFF Manual FRE status is memorized. AUTO control OFF OFF AUTO control AUTO control Display Setting 71 More sensitive setting than display 72 setting (the change to REC is earlier than display 72 operation.) 72 More sensitive setting than normal setting (the change to REC is earlier than normal operation.) 73 (Initial status) Normal |