Content .. 1148 1149 1150 1151 ..
HEATER & COOLING UNIT ASSEMBLY HA-113 < REMOVAL AND INSTALLATION > [VK50VE] C D E F G H J K L M A B HA N O P CAUTION: • Replace O-rings with new ones. Then apply compressor oil to them when installing. straight in axial direction. • Insert piping securely until a click is heard. does not come loose. • O-rings differ from low-pressure flexible hose (high-pressure pipe 1) and low-pressure pipe 1 (high- pressure pipe 2). • Mark the mounting position of intake sensor bracket prior to removal so that the reinstalled sensor can be located in the same position. • Check for leakages when recharging refrigerant. EXPANSION VALVE EXPANSION VALVE : Removal and Installation INFOID:0000000005249979 REMOVAL 1. Remove low-pressure pipe 1 and high-pressure pipe 2. Refer to 2. Remove mounting bolts (A), and then remove expansion valve CAUTION: Cap or wrap the joint of evaporator and expansion valve INSTALLATION Installation is basically the reverse order of removal. CAUTION: • Replace O-rings with new ones. Then apply compressor oil to them when installing. pressure pipe 2). • Check for leakages when recharging refrigerant. JPIIA0710ZZ |