• TEMP DOOR 

• MODE DOOR 

• INTAKE DOOR 

• BLOWER FAN SPEED 

• A/C 

2. When the AUTO mode is off, the word AUTO should 

not appear. 

3. After off the AUTO mode, the system is automatically 

controlled except for the manually selected SW. 

OFF SW AND SYSTEM OPERATION 

- OFF: SYSTEM OFF 

- FAN UP/DOWN: BLOWER FAN SPEED MANUAL 

CONTROL 

- MODE: DISCHARGE MODE MANUAL CONTROL 

- A/C: A/C ON/OFF MANUAL CONTROL 

- FRE.: FRE. MODE MANUAL CONTROL 

- REC.: REC. MODE MANUAL CONTROL 

- DEF.: DEF. MODE MANUAL CONTROL, A/C ON, 

FRE. 

AMB 

Ambient 
temperature 
display 

• "AMB": 

Display 

• Ambient 

temperature: 
Display 

• The other 

signals: OFF 

1. System is operated as the same before the AMB SW 

turned on. 

2. When the AMB SW is pushed, the other signals are 

not appearedbut the word AMB and the ambient 
temperature are displayed for 5 sec., andthen the 
display become the same as the AMB SW is not 
pushed. 

OFF SW AND SYSTEM OPERATION 

- AMB: If the AMB SW is pushed once more when the 

ambient temperatureis displayed, the ambient 
temperature does not appear and the display 
becomethe same as the AMB SW is not pushed. 

- OTHER SWITCHES: If the other switch is pushed 

except for REARDEF and in-car & ambient /AQS, 
ambient temperature does not appear and the pushed 
switch is displayed. 

A/C 

A/C ON/OFF 
CONTROL 

• "A": 

Display/OFF 

• "AUTO": 

OFF 

1. A/C ON/OFF 

OFF SW AND SYSTEM OPERATION 

- A/C: A/C ON/OFF MANUAL CONTROL 

- OFF: SYSTEM OFF 

- AUTO: AUTO MODE AUTOMATIC CONTROL 

MODE 

MODE DOOR 
CONTROL 

• VENT 

• B/L 

• FOOL 

• MIX 

• "MODE": 

Display/OFF 

• "AUTO": Off 

1. Fix the MODE DOOR to one among VENT, B/L, 

FLOOR and MIX. 

2. MODE SW MANUAL CONTROL ORDER : VENT 

 

B/L 

 FLOOR 

 MIX 

 VENT 

 ... 

3. At MIX MODE: MIX LOGIC (MIX, FRE., A/C ON) 

OFF SW AND SYSTEM OPERATION 

- DEF: DEF MODE MANUAL CONTROL 

- MODE: VENT, B/L, FLOOR & MIX (repeat the order) 

- AUTO: AUTO MODE AUTOMATIC CONTROL 

DEF 

DEF MODE 

• "DEF": ON 

• "A/C": 

Display 

• REC. IND: 

OFF 

1. MODE DOOR: Fix to "DEF" 

2. INTAKE DOOR: Fix to "FRE." (REC. can be selected) 

3. A/C: ON 

• A/C OUTPUT ON/OFF control: Corresponding to 

the detected temperatureby EVAP SENSOR. 

• "AUTO": 

OFF 

• A/C output should be cut off at 3.5°C or below 

(ambient temperature). 
(DISPLAY OFF, A/C SELECT SIGNAL OFF) 

4. DEF is prior to "MAX HOT/COOL" function. 

5. DEF is prior to "MIX MODE" control. 

OFF SW AND SYSTEM OPERATION 

- AUTO: ALL SYSTEM AUTOMATIC CONTROL 

- MODE: DISCHARGE MODE MANUAL CONTROL 

(DEF Function off) 

- A/C: A/C ON/OFF MANUAL CONTROL 

- DEF: Return to the mode before the DEF S/W 

selection 

OFF 

SYSTEM OFF 

LCD: ON 

1. BLOWER FAN SPEED OFF 

2. A/C OFF 

3. TEMP. DOOR: Fix to the mode before OFF 

4. MODE DOOR: Fix to the mode before OFF 

5. INTAKE CONTROL: Fix to the mode before OFF 

6. After "OFF", at REC, REC. S/W ON (NON-AQS type) 

- Shift to FRE. MODE 

- REC. INDICATOR ON 

- LCD OFF 

- OTHERS: OFF 

7. After "OFF", at FRE, FRE. S/W ON (NON-AQS type) 

- Shift to FRE. MODE 

- REC. INDICATOR ON 

- LCD OFF 

- OTHERS: OFF 

8. After "OFF", at AQS, AQS/REC. S/W ON (AQS type) 

- Shift to REC. MODE 

- AQS OFF 

- REC. INDICATOR ON 

- LCD OFF 

- OTHERS: OFF 

9. After "OFF", AQS ON

AQS LOGIC 

10. After "OFF", AMB S/W ON 

- OFF: The word "AMB" & ambient temperature 

displays for 5 sec. and then off. 

OFF SW AND SYSTEM OPERATION 

• AUTO: AUTO MODE AUTOMATIC CONTROL 

• BLOWER 

- SPEED: Return to MANUAL LOW 

- OTHERS: Return to the mode before OFF 

• A/C 

- A/C ON 

- OTHERS: Return to the mode before OFF 

• MODE 

- MODE: The mode before OFF 

- OTHERS: Return to the mode before OFF 

• DEF 

- MODE: DEF 

- A/C ON 

- INTAKE: FRE. 

- OTHERS: Return to the mode before OFF 

• TEMP 

SIGNAL I/O FOR EACH CONTROL FEATURE 

 

- TEMP: The mode before OFF 

- OTHERS: Return to the mode before OFF 

REC. (NON-
AQS type) 

REC. MODE 

• IND ON 

• "AUTO" 

display 

1. When operating the REC. S/W from FRE. MODE, fix 

the INTAKE DOORto REC. MODE or when operating 
the REC. S/W from REC., fix the INTAKE DOORto 
FRE. MODE. 

FRE. MODE 

• IND OFF 

• "AUTO" 

display 

OFF SW AND SYSTEM OPERATION 

- REC.: FRE./REC. MODE CONTROL 

- OFF SW: ALL MODES (POSSIBLE TO MANUALLY 

SELECT) 

- AUTO: AUTOMATIC CONTROL (FRE. or REC.) 

FAN UP/DOWN  BLOWER FAN 

SPEED 
UP/DOWN 

FAN IND 
ON/OFF 

1. BLOWER MOTOR's rotation speed is controlled by the 

current variationof the POWER TRANSISTOR. 

2. At AUTO MODE, if FAN is operated UP/DOWN, the 

FAN SPEED is UP/DOWNon the basis of the present 
FAN LEVEL. 

3. At OFF, if the other SW except for "FAN" is turned ON, 

the FAN SPEED is gradually increased from LOW to 
TARGET SPEED 

4. Fan speed level and voltage 

• AUTO AIR CONDITIONER: No level (4.5V - B+) 

• AUTO HEATER: No level (4.5V - B+) 

• MANUAL FAN SPEED: 7th level (3.8V - B+) 

5. The first shift to another step takes 0.7 sec. If the 

button iscontinually engaged, the first shift takes 0.7 
sec. And then the next ones take 0.3 sec per each. 
The operation sound is made for 0.1 sec. 

6. At MANUAL 7th level when the UP SW is pushed or at 

MANUAL 1st level when the DOWN SW is pushed, the 
operation sound is made 5 times at an interval of 0.15 
sec. 

7. When shifting 6 to 7 level, or 2 to 1 level, the operation 

soundis intervally made each 0.15 sec. 

OFF SW AND SYSTEM OPERATION 

- AUTO: AUTO MODE AUTOMATIC CONTROL 

- OFF: SYSTEM OFF 

- FAN UP/DOWN: BLOWER FAN SPEED MANUAL 

CONTROL 

10  DEFOG 

Rear glass 
defogger 

DEFOG IND 
ON/OFF 

1. If the DEFOG SW is pushed, the rear glass defogger 

operation signal is output to the ETACS and the 
ETACS turns the DEFOG IND on by the HTD input. 

2. While operating the rear glass defogger, if DEFOG SW 

is pushed, ETACS stops operating the rear glass 
defogger and turns the DEFOG IND off. 

3. After operating the rear glass defogger for 15 minutes 

by EATCS, DEFOG function is automatically off. 

OFF SW AND SYSTEM OPERATION 

- DEFOG: Push the second DEFOG SW, DEFOG 

function is off. 

SYSTEM CONTROL FEATURES

Control item 

Input 

Output 

Remarks 

Required discharge 

Auto SW, A/C SW, TEMP SW, INCAR 

TEMP actuator 

 

During mode control, the A/C may operate during DEF or MIX mode.In order to enable dehumidification, the driver may 
select A/C OFF duringthe A/C on condition. 
CONTROL SPECIFICATION 

temperature control 

sensor,AMB sensor, Photo sensor, Water 
temperature sensor, thermo sensor, TEMP 
actuator. 

Mode control 

AUTO SW, MODE SW, TEMP SW, DEF 
SW,Blower SW, OFF SW, INCAR sensor, AMB 
sensor, Photo sensor, Water 
temperaturesensor, thermo sensor, Power TR. 

Blower motor 
Power TR 
HI-blower relay 

Blower Switch 
Manual selection 
Control in priority 

Mode door control 

AUTO SW, MODE SW, DEF SW, Blower 
SW,OFF SW, TEMP SW, INCAR sensor, AMB 
sensor, Photo sensor. 

Mode actuator 

Intake control 

AUTO SW, A/C SW, DEF SW, TEMP SW,OFF 
SW, Intake SW, INCAR sensor, AMB sensor, 
Photo sensor, Power TR. 

Mode actuator 

Compressor control 

AUTO SW, A/C SW, DEF SW, TEMP SW,OFF 
SW, IN-CAR sensor, AMB sensor, Photo 
sensor. 

Compressor relay 

Control item 

Control features 

Remarks 

Required 
discharge 
temperature 

Required temperature determined by the set temperature and the 
inputted sensor value. 

Auto control 

Required discharge temperature is determined by the set temperature 
and the inputted sensor value. The feature will use the required 
discharge temperature to perform the auto control of temp. actuator, 
mode actuator, intake actuator, blower motor and compressor, and 
maintain the set temperature stably. 

IN-CAR 
temperature 
correction 

Upon detecting rapid changes of temperature from the INCAR sensor, it 
will gradually correct the incar temperature value. 

- 1°C UP/4sec delay 

- 1°C DOWN/4sec delay 

AMB 
temperature 
correction 

Upon detecting rapid changes of temperature from the AMB sensor, it 
will gradually correct the ambient temperature value. 

- 1°C UP/3min delay 

- 1°C DOWN/4sec delay 

Photo correction  Upon detecting rapid changes of photo intensity from the PHOTO 

sensor, it will gradually correct the photo intensity value. 

- 350 

 1000(W/m²)/1min 

delay 

- 350 

 1000(W/m²)/5min 

delay 

TEMP door 
control 

It does the automatic control to maintain the optimum TEMP door 
opening (0%-100%).It will be computed by the temperature set and the 
input signal from each sensor. 

The set temperature range 
17°C 

 32°C, 0.5°C step 

(62°F 

 90°F, 1°F step) 

Blower speed 

Automatic control of the blower speed. The target value will be 
computed by the set temperature and the input signal from each sensor. 
(7 levels may be selected in case of manual selection.) 

- Auto mode blower low 

voltage (Manual low 
voltage: 3.8) 

- Auto mode heater blower 

HI speed: 10.6V 

Electro-motive 
mode control 

During auto control, it will raise the permitted voltage of blower motor 
gradually in order to improve comfortability. 

6 seconds for shifting LO 

 

MAX 

Photo 
compensation 

During auto control, it will compensate the blower level and the 
discharge temperature according to the photo intensity detected from 
the PHOTO sensor at VENT or B/L mode. PHOTO compensation will 
begin after 5 seconds when ignition on. 

Mode door 

Automatic control of air discharge based on the required discharge 

- At OFF in AUTO mode, 

 

 

 

 

 

 

 