Geely Emgrand X7. Manual part - 206

 

  Главная      Geely     Geely Emgrand X7 - Manual

 

поиск по сайту            

 

 

 

 

 

 

 

 

 

 

 

 

содержание   ..   201  202  203  204  205  206  207  ..

 

 

Geely Emgrand X7. Manual part - 206

 

 

 

(a)  Connect fault diagnosis tester to the diagnostic interface. 

(b)  Turn ignition switch to ON position. 

(c)  Clear DTC code. 

(d)  Start and run the engine at idle speed to warm up the engine for at least 5 min. 

(e)  Road test the vehicle for at least 10 min. 

(f)  Read control system DTC code again to confirm that the system has no DTC code. 

 

Step 18

  Troubleshooting 

5. Maintenance 

guide: 

Refer to 2.10.7.4 Replacement of Spark Plug to replace the spark plug. 

Step 17

 

Use a fault diagnosis tester to confirm whether the DTC Code is stored again. 

No 

Refer to 2.12.7.3 Intermittent Fault 
Inspection for intermittent fault. 

Yes 

Next 

823

2.12.7.34 DTC P0324P0325 

1. DTC 

description: 

DTC  P0324 

Knock Control System Fault 

DTC  P0325 

Knock Sensor Fault 

KS sensor to ECM feedback signal helps ECM control the ignition timing to achieve the optimal 
operation and the ignition system to achieve the best performance, as well as to prevent damage to 
the engine by a potential knock. KS sensor is located below the intake manifold on the cylinder. 
KS sensor voltage changes with the AC signal generated by the vibration with running engine. 
Engine control module adjusts spark timing according to KS sensor signal amplitude and 
frequency. 

ECM receives signals from KS sensor harness connector EN08 terminal No.1 and 2 through ECM 
harness connector EN01 terminal No.36 and 37. 

2.  Conditions For Setting DTC and The Fault Location: 

DTC Code 

DTC Detection 
Strategy 

Conditions For Setting The 
DTC (Control Strategy) 

Fault Locations 

P0324 

Knock Control 
System Fault 

1.  Engine speed is higher 

than 1,600 rpm. 

2. Certain 

Load 

Conditions.

3.  Any section of the sensor 

signal circuit is short to 
ground. 

P0325 

Knock Sensor 
Fault 

1.  Engine speed is higher 

than 1,600 rpm. 

2. Certain 

Load 

Conditions.

3. Sensor Signal Circuit 

Open. 

1. Sensor 

Circuit 

2. Sensor 

3. ECM. 

824

3. Circuit 

sketch 

NL02-2101b

36

EN01

1

EN08

2

EN08

37

EN01

爆震传感器

ECM

KNOCK HI

KNOCK LO

 

4. Diagnostic 

Steps: 

Note: Before carrying out this diagnosis step, observe the data list on fault diagnosis tester and 
analyze the accuracy of the data, as these will help with quick diagnosis. 

Step 1

 

Initial Inspection 

(a)  Inspect whether there is KS sensor physical damage. 

(b)  Inspect whether KS sensor is installed correctly. Torque is set too tight or too loose will 

trigger DTC codes. 

(c)  Check KS sensor installation surface whether there are glitches, casting flash and foreign 

matter. 

(d)  Knock sensor must be kept away from hoses, brackets and engine wires. 

Are these components normal? 

 

(a)  Connect fault diagnosis tester to diagnostic interface. 

(b)  Turn ignition switch to ON position. 

(c)  Select Engine/Read Data/Knock Sensor Signal 1. 

(d)  Start and run the engine at normal working temperature. 

Step 2

 

Read the engine data (engine speed) on the fault diagnosis tester. 

No 

Repair the faulty part. Go to step 9 

Yes 

Knock sensor 

825

(e)  Road test the vehicle and read the engine speed data on the fault diagnosis tester. 

Is the data normal? 

Standard Value: Normal data. Refer to 2.12.7.9 Data Flow Table 

 

Step 3

 

Refer to 2.12.7.4 Fault Symptom Table for intermittent fault. 

 

Step 4

 

Inspect Knock Sensor 

(a)  Rotated ignition switch to OFF position . 

(b)  Disconnect Knock Sensor harness connector EN08. 

(c)  Measure knock sensor resistance. 

Standard Resistance: 

It is above 1MΩ with 1MΩ 

(d)Connect Knock Sensor harness connector EN08. 

Is the resistance normal? 

 

Step 5

 

Inspect sensor terminal No.1 circuit. 

 

(a)  Rotated ignition switch to OFF 

position . 

(b) 

Disconnect Knock Sensor 
harness connector EN08. 

(c) 

Disconnect ECM harness 
connector EN01. 

(d) Measure  resistance  between 

knock sensor harness connector 
EN08 terminal No.1 and ECM 
harness connector EN01 terminal 
No.36. Inspect whether the 
circuit is open. 

NL02-2102b

1

2

EN08 爆震传感器线束连接器

1

No 

Refer to 2.10.7.5 “Replacement of Knock Sensor” 
to replace the knock sensor. Go to Step 9. 

Yes 

No 

Go to step 4 

Yes 

EN08 knock sensor harness connector 

826

 

 

 

 

 

 

 

 

 