содержание .. 161 162 163 164 165 ..
Geely EC718, EC718RV, EC715, EC715RV. Manual part - 164
Next Step 8 Diagnostic completed. 2.11.7.9 Battery Discharging Current Parasitic Load Test If the battery continues to loss power, perform the following test to check whether there are parasitic battery current. Note Before carry out this procedure, please check whether there are installed after market equipments such as DVD, audio Warning! Refer to "Battery Disconnection Warning" in "Warnings and Notices". Step 1 Disconnect the battery negative cable. Refer to . Next Step 2 With a digital multimeter, connect one end to the battery negative cable, the other to the negative battery Next Step 3 Select digital multimeter's "current test" maximum range. Next Step 4 Left open the front door to observe the meter display readings. Note Do not carry out any other operations action at this time, otherwise Next Step 5 If the multimeter has no display, check whether the meter is damaged. If there is displayed reading, close Next Step 6 Observe the body Anti-theft system lamp the indicating system is in alert mode. Next Step 7 Wait for more than 10 min to observe the meter readings, (if the multimeter shows an abnormal reading, Engine Starting / Charging System JL4G18-D 2-571 |