13–01 Air Compressor

Inspection, Holset

Inspect the air intake line, oil supply and return lines,
and coolant supply and return hoses for tight connec-
tions and general condition. Tighten the connections,
and replace the lines and hoses, as needed. If the
compressor air-intake adapter is loose, remove the
adapter, replace its gaskets, and securely install it.

Check the cooling fins on the compressor crankcase.
Clean the fins if they are clogged with debris.

Air Compressor

13

Cargo Maintenance Manual, January 2000

13/1

Title of Maintenance Operation (MOP)

MOP Number

Alternator and Starter Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15–01

Alternators and Starters

15

Index, Alphabetical

Cargo Maintenance Manual, January 2000

15–01 Alternator and Starter

Check

1.

Check the tightness of the alternator bracket fas-
teners; tighten the fasteners as needed. For
torque values, see Group 15 of the

Cargo Work-

shop Manual

.

2.

Clean and tighten all charging system electrical
connections as needed.

3.

Check the alternator wiring for missing insulation,
kinks, and heat damage. Replace or repair as
needed.

4.

Check the battery cable connections to and from
the starter solenoid and cranking motor for tight-
ness. Check the tightness of all ground straps
and cable fasteners. Make sure they are free of
corrosion.

5.

Make sure that the starter mounting bolts are
tight. If loose, tighten them 38 lbf·ft (52 N·m).

6.

Check the alternator charging voltage.

NOTE: Batteries must be fully charged in
order to check alternator charging voltage.

6.1

Check the charge level of the batteries;
for instructions, see Group 54 in the

Cargo Workshop Manual

. Charge the bat-

teries as needed.

6.2

Turn off all vehicle loads (such as the
lights, heater, and air conditioner), and
connect an accurate voltmeter across the
batteries. Run the engine at fast idle, ap-
proximately 1000 rpm, for about two min-
utes to stabilize voltage output.

7.

If the voltmeter reading rises above 15.0 volts
and cannot be lowered, replace the alternator.

If the output voltage does not rise above 12.8
volts, and cannot be increased when the engine
is running, see Group 15 of the

Cargo Workshop

Manual

for troubleshooting and replacement in-

structions.

Alternators and Starters

15

Cargo Maintenance Manual, January 2000

15/1

Title of Maintenance Operation (MOP)

MOP Number

Radiator Cap Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20–01