419-10-12 Body Electronics Module (BEM) 419-10-12 DIAGNOSIS AND TESTING (Continued) DTC Description Precondition Action B1549 Power Window Master Power Window Relay Check Power window Circuit Short To Battery driver S/C to Battery, relay and wiring External Fault B1600 PATS Ignition Key TILA RF receiver error Check power available on Transponder Signal Is J1/4 & earth on J1/3. Not Received Check continuity from BEM J1/7 to TILA J6/1. Check TILA. B1601 PATS Received Incorrect Key ID unknown or Check programmed key Key-Code From Ignition Incorrect challenge is used. Reprogram keys Key Transponder if required. B1602 PATS Received Invalid Faulty or fixed code Program correct Format Of Key-Code transponder transponder Key From Ignition Key Transponder B1693 Autolamp On Circuit Autoheadlamps Driver Twilight sensor Headlamp Failure Circuit Failure, External switch must be in Auto Fault. position. Check Wiring and headlamp switch and headlamp relay. B1790 Autolamp Sensor Input Twilight sensor input Check operation of Circuit Failure circuit failure battery saver. Check Twilight sensor and wiring B1791 Autolamp Sensor Input Twilight sensor input Check Twilight sensor Circuit Open circuit open, External and wiring Fault B1982 Driver’s Door Unlock Driver’s door unlock is Pinpoint tests G and N. Relay Circuit Failure not successful / Driver’s door lock feedback did not change after unlock action B2072 Seat Memory Module S/C to Battery, External Check Seat memory Data Line Short to Battery Fault module and wiring J2/22 Check option is fitted B2073 Seat Memory Module O/C or S/C to Ground, Check Seat memory Data Line Open or Short External Fault module and wiring J2/22 to Ground Check option is fitted B2074 Seat Memory Module S/C to Battery, External Check Seat memory Enable Line Short to Fault module and wiring J2/23 Battery Check option is fitted 2075 B Seat Memory Module O/C or S/C to Ground, Check Seat memory Enable Line Open or External Fault module and wiring J2/23 Short to Ground Check option is fitted B2103 Antenna Not Connected TILA antenna not Check power available on connected, External Fault J1/4 & earth on J1/3. Check continuity from BEM J1/7 to TILA J6/1. Check TILA. B2141 NVM Configuration No PCM ID Stored Conduct a parameter Failure reset B2431 Transponder Key programming failed Program new key. If this Programming Failed fails try new transponder. If this still fails try a new TILA. G43561 en |