418-00-11 Module Communications Network 418-00-11 DIAGNOSIS AND TESTING (Continued) Test Step Result / Action to Take D3 CHECK FOR CORRECT PAM OPERATION Disconnect all PAM connectors. Yes INSTALL a new PAM module. Refer to section Check for: 413-13. CARRY OUT the DATA LINK Corrosion DIAGNOSTICS test. Pushed-out pins No The system is operating correctly at this time. Connect all PAM connectors and make sure they seat correctly. Concern may have been caused by a loose, or a Operate the system and verify the concern is still present. corroded connector. CLEAR the DTCs. REPEAT Is the concern still present? PINPOINT TEST E : IC MODULE DOES NOT RESPOND TO THE DIAGNOSTIC TOOL (WDS) refer to module connector diagram in chapter 413-01. Test Step Result / Action to Take E1 CHECK IC C171 CAN CIRCUITS 914L (BR-Y) and 915L (P-L) FOR DAMAGE Key in OFF position. Yes Go to E2 Disconnect IC C171. No Inspect IC C171 for damage. REPAIR IC C171. CARRY OUT the DATA LINK Is the IC C171 OK? DIAGNOSTICS test. E2 CHECK CAN HIGH AND CAN LOW CIRCUITS 914L (BR-Y) AND 915L (P-L) BETWEEN DLC C174 AND IC C171 FOR OPEN Measure the resistance between IC module C171, circuit 914L Yes (BR-Y), harness side and DLC C174, circuit 914K (BR-Y), harness Go to E3 side. No Measure the resistance between IC module C171, circuit 915L (P-L), REPAIR the circuit(s) in question. CARRY OUT harness side and DLC C174, circuit 915K (P-L), harness side. the DATA LINK DIAGNOSTICS test. Are the resistances less than 5 ohms? E3 CHECK FOR CORRECT IC OPERATION Disconnect all IC connectors. Yes INSTALL a new IC module. Refer to section Check for: 413-01. CARRY OUT the DATA LINK Corrosion DIAGNOSTICS test. Pushed-out pins No The system is operating correctly at this time. Connect all IC connectors and make sure they seat correctly. Concern may have been caused by a loose, or a Operate the system and verify the concern is still present. corroded connector. CLEAR the DTCs. REPEAT Is the concern still present? G86728 en |