cannot be identified at this time. If TP V PID voltage does not increase smoothly during throttle TEST DJ: AIR CONDITIONING EVAPORATOR TEMPERATURE SENSOR Diagnostic Aids Perform this test only when directed by QUICK TEST. This test is intended to diagnose the following: z Air Conditioning Evaporative Temperature (ACET) Sensor z Wiring Harness Circuits (ACET & SIG RTN) z Powertrain Control Module (PCM) DTC P1437 is set when ACET signal is more than self-test maximum of 4.5 volts. DTC P1436 is set when ACET SENSOR SPECIFICATIONS (1)
NOTE: After each service or repair procedure has been completed, reconnect all NOTE: ACET sensor may also be referred to as an Evaporator Air Discharge Temperature °F (°C) Volts Ohms -4 (-20) 4.66 276,960 14 (-10) 4.45 160,310 32 (0) 4.14 95,850 50 (10) 3.73 58,990 68 (20) 3.26 37,340 86 (30) 2.74 24,250 104 (40) 2.23 16,110 122 (50) 1.77 10,930 140 (60) 1.37 7550 158 (70) 1.05 5340 176 (80) .80 3840 194 (90) .61 2800 212 (100) .47 2080 (1) Value may vary by 15 percent due to sensor and VREF variations. Voltage values are calculated for