TEST ACTION APPLICABILITY 6 Turn the ignition off. All Yes → Repair the short to ground in the (K125) Generator Field Source circuit and replace the PCM. No → Go To 7 7 Measure the resistance of the (K20) Generator Field Driver circuit from the All Yes → Go To 8 No → Repair the open in the (K20) Generator Field Control circuit. Perform POWERTRAIN VERIFICATION TEST VER - 3. 8 Measure resistance across the Generator Field Terminals at the Generator. All Yes → Replace or repair the Generator as necessary. Perform POWERTRAIN VERIFICATION TEST VER - 3. No → Go To 9 9 NOTE: Before continuing, check the PCM harness connector terminals for All Repair Replace and program the Powertrain Control Module per Service 179 DRIVEABILITY - GAS P1682-CHARGING SYSTEM VOLTAGE TOO LOW — Continued |