MODE 1 CIRCUIT SHORTED TO GROUND When Monitored: When the Actuator Circuit Test is executed. Set Condition: This message will set if the A/C - Heater Control detects a short low on the Mode Door 1 Driver circuit. MODE 1 CIRCUIT SHORTED TO IGN OR BATT When Monitored: When the Actuator Circuit Test is executed. Set Condition: This message will set if the A/C - Heater Control detects a short high on the Mode Door 1 Driver circuit. MODE 2 CIRCUIT SHORTED TO GROUND When Monitored: When the Actuator Circuit Test is executed. Set Condition: This message will set if the A/C - Heater Control detects a short low on the Mode Door 2 Driver circuit. MODE 2 CIRCUIT SHORTED TO IGN OR BATT When Monitored: When the Actuator Circuit Test is executed. Set Condition: This message will set if the A/C - Heater Control detects a short high on the Mode Door 2 Driver circuit. RECIRC CIRCUIT SHORTED TO GROUND When Monitored: When the Actuator Circuit Test is executed. Set Condition: This message will set if the A/C - Heater Control detects a short low on the Recirculation Door Driver circuit. RECIRC CIRCUIT SHORTED TO IGN OR BATT When Monitored: When the Actuator Circuit Test is executed. Set Condition: This message will set if the A/C - Heater Control detects a short high on the Recirculation Door Driver circuit. SHORT TOO COMPLEX When Monitored: When the Actuator Circuit Test is executed. Set Condition: This message will set if the A/C - Heater Control detects more than three drivers being shorted in the same direction (for example, four drivers, all shorted to POSSIBLE CAUSES DOOR DRIVER CIRCUIT SHORTED LOW DOOR ACTUATOR SHORTED 209 HEATING & A/C ACT CKT TEST PASSED, OVERCURRENT DTCS ACTIVE — Continued |