Dodge Ram. Manual - part 120

 

  Index      Dodge     Dodge Ram - service manual 2004 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  118  119  120  121   ..

 

 

Dodge Ram. Manual - part 120

 

 

TEST

ACTION

APPLICABILITY

3

Disconnect the Instrument Cluster C2 connector.
Measure the voltage between Passenger Door Lock Switch Mux circuit and ground.
Is there any voltage present?

All

Yes

→ Go To 4

No

→ Replace the Instrument Cluster.

Perform BODY VERIFICATION TEST - VER 1.

4

Disconnect the Passenger Door Lock Switch connector.
Disconnect the Instrument Cluster C2 connector.
Measure the voltage between Passenger Door Lock Switch Mux circuit and ground.
Is there any voltage present?

All

Yes

→ Repair the Passenger Door Lock Switch Mux circuit for a short to

voltage.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Test Complete.

5

Disconnect the Passenger Door Lock Switch connector.
Using a 12-volt test light connected to 12-volts, check the Ground circuit.
Does the test light illuminate brightly?

All

Yes

→ Go To 6

No

→ Repair the Ground circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

6

Disconnect the Passenger Door Lock Switch connector.
Measure the voltage between Passenger Door Lock Switch Mux circuit and ground.
Is the voltage above 4.6 volts?

All

Yes

→ Go To 7

No

→ Repair the Passenger Door Lock Switch Mux circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

7

If there are no possible causes remaining, view repair.

All

Repair

Replace the Door Lock Switch.
Perform BODY VERIFICATION TEST - VER 1.

477

POWER DOOR LOCKS/RKE

PASSENGER DOOR LOCK SWITCH INPUT CIRCUIT OPEN OR SHORT
TO VOLTAGE —

Continued

Symptom:

PASSENGER DOOR LOCK SWITCH INPUT CIRCUIT SHORTED

When Monitored and Set Condition:

PASSENGER DOOR LOCK SWITCH INPUT CIRCUIT SHORTED

When Monitored:

At all times when battery power is supplied to the Instrument Cluster.

Set Condition:

When the Instrument Cluster senses voltage to the passenger door lock

switch below .25 volts, the input circuit is not valid and this code will set.

POSSIBLE CAUSES

DTC PRESENT

DOOR LOCK SWITCH SHORTED

DOOR LOCK SWITCH MUX SHORTED

INSTRUMENT CLUSTER - - PASSENGER DOOR LOCK SWITCH INPUT SHORTED

TEST

ACTION

APPLICABILITY

1

Turn the ignition on.
With the DRBIII

t, record and erase DTC’s.

With the DRBIII

t, read DTC’s.

Operate the door locks several times from the Passenger Door Lock Switch while
monitoring the DRBIII

t.

Does the DRBIII

t display PASS DOOR LOCK SW INPUT CIRCUIT SHORTED?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.

2

Disconnect the Door Lock Switch connector.
With the DRBIII

t in Sensors, read the PASS DOOR LOCK SW MUX circuit

Is the voltage above 4.6 volts?

All

Yes

→ Replace the Door Lock Switch.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

3

Disconnect the Passenger Door Lock Switch connector.
Disconnect the Instrument Cluster C2. connector.
Measure the resistance between Passenger Door Lock Switch Mux circuit and
ground.
Is the resistance below 1000.0 ohms?

All

Yes

→ Repair the Passenger Door Lock Switch Mux circuit for a short to

ground.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

478

POWER DOOR LOCKS/RKE

TEST

ACTION

APPLICABILITY

4

If there are no possible causes remaining, view repair.

All

Repair

Replace the Instrument Cluster.
Perform BODY VERIFICATION TEST - VER 1.

479

POWER DOOR LOCKS/RKE

PASSENGER DOOR LOCK SWITCH INPUT CIRCUIT SHORTED —

Continued

Symptom:

PASSENGER DOOR LOCK SWITCH INPUT CIRCUIT STUCK

When Monitored and Set Condition:

PASSENGER DOOR LOCK SWITCH INPUT CIRCUIT STUCK

When Monitored:

At all times when battery power is supplied to the Instrument Cluster.

Set Condition:

When the instrument cluster senses voltage to the passenger door lock

switch between 1.3 and 3.95 for over 20 seconds, this code will set.

POSSIBLE CAUSES

DTC PRESENT

INSTRUMENT CLUSTER - DOOR LOCK SWITCH VOLTAGE INCORRECT

DOOR LOCK SWITCH MUX CIRCUIT PARTIAL SHORT TO GROUND

DOOR LOCK SWITCH STUCK

TEST

ACTION

APPLICABILITY

1

Turn the ignition on.
With the DRBIII

t, record and erase DTC’s.

With the DRBIII

t, read DTC’s.

Operate the door lock several times from the Passenger Door Lock Switch while
monitoring the DRBIII

t.

Does the DRBIII

t display Pass DOOR LOCK SW INPUT STUCK?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors. Check the door lock switch for a possible
intermittent sticking condition
Perform BODY VERIFICATION TEST - VER 1.

2

With the DRBIII

t in Sensors, read the PASS DOOR LOCK SW MUX voltage.

Does the DRBIII

t display voltage between 1.3 and 3.95 volts?

All

Yes

→ Go To 3

No

→ Replace the Instrument Cluster.

Perform BODY VERIFICATION TEST - VER 1.

3

Disconnect the Passenger Door Lock Switch connector.
Measure the voltage between Door Lock Switch Mux circuit and ground.
Is the voltage above 4.6 volts?

All

Yes

→ Test Complete.

No

→ Repair the Passenger Door Lock Switch Mux circuit for a partial

short to ground.
Perform BODY VERIFICATION TEST - VER 1.

480

POWER DOOR LOCKS/RKE

 

 

 

 

 

 

 

Content   ..  118  119  120  121   ..