7A – 12 I HEATING AND VENTILATION SYSTEM DAEWOO V–121 BL4 Step No Yes Value(s) Action 8 Adjust or repair the floor/defroster and/or the vent/ System OK 9 Is there objectionable vent bleed? Go to Step 10 Go to Step 15 10 1. Check the system case for leaks. Are there problems? Go to Step 11 Go to Step 12 11 Repair the system case or the floor outlet attach- System OK Go to Step 12 12 1. Turn the ignition OFF. to full cold. 3. Listen for the sound of the temperature door slam just before reaching the end of the travel Does the door slam? Go to Step 13 Go to Step 14 13 Adjust the vent door to allow more ventilation. System OK 14 1. Check the temperature door travel, the cable, and the linkage. 2. Verify that the temperature door goes to full cold. 3. Check the temperature door for full hot. Is the temperature door travel correct? System OK 15 1. Turn the fresh air/recirculating air control to fresh air (indicator lamp OFF). 2. Turn the temperature control knob to full cold. up. 4. Measure the air temperature at the blower in- let, or cowl, and at the vent air outlet inside the Is the outlet air more than 5 ° C (41 ° F) warmer than the inlet air? Go to Step 16 System OK 16 1. Check for hot air leaks from the engine compartment to the blower inlet. 2. Repair, as needed. Is the repair complete? System OK
|