DAF 95XF. Manual - part 226

 

  Index      DAF     DAF 95XF Series - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  224  225  226  227   ..

 

 

DAF 95XF. Manual - part 226

 

 

5

Contents

DIAGNOSIS

1

CONTENTS

Page

Date

1.

BATTERIES

1-1

9711

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . .

1.1

Fault-finding table

1-1

9711

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . .

2.

TROUBLESHOOTING

2-1

9711

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . .

2.1

Short circuits

2-2

9711

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . .

2.2

Open circuits

2-3

9711

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . .

2.3

Earthing problems

2-4

9711

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . .

1

ǹ 9711

5

DIAGNOSIS

Contents

2

1

ǹ 9711

5

Batteries

DIAGNOSIS

1-1

1. BATTERIES

1.1 FAULT-FINDING TABLE

FAULT: NEW BATTERY GETS QUITE HOT DURING CHARGING

Possible cause

Remedy

Inadequate formation because of bad
conservation or long-term (moist) storage

Allow battery to cool down
Charge properly
Check density

FAULT: ELECTROLYTE LEVEL TOO LOW

Possible cause

Remedy

Leaking battery box

Replace battery

Excessive gas production caused by
overcharging

Check/repair charger

FAULT: BATTERY ACID SPILLS FROM THE PLUG HOLES

Possible cause

Remedy

Battery level exceeds capacity

Siphon off liquid

Overcharging

Check charger and repair, if necessary

FAULT: DENSITY IS TOO LOW (

<1,240)

BAD STARTING

Possible cause

Remedy

Power user left on

Charge battery

Insufficient charge

Check/repair charger

Short circuit in the charging circuit

Check charging circuit

FAULT: DENSITY IS TOO HIGH (

<1,290)

Possible cause

Remedy

Topped up with acid instead of distilled water

Siphon off liquid and top up with distilled water
If necessary, repeat after mixing (charging)

1

ǹ 9711

5

DIAGNOSIS

Batteries

1-2

FAULT: BAD STARTING

BAD STARTING TEST

POWER FAILS UNDER LOAD

Possible cause

Remedy

-

Discharged battery

Charge battery

-

Worn battery (corroded plates)

Replace battery

-

Defective battery (“dead cell”)

Replace battery

-

Battery too small

Install battery with a larger capacity

-

Sulphated battery (plates are hard)

Replace battery

FAULT: BURNT-IN BATTERY TERMINALS

Possible cause

Remedy

-

Wire clamps not securely fitted or bad
contact

Have battery terminals repaired, securely fit wire
clamps, and replace clamps, if necessary

FAULT: EXCESSIVE BUBBLING IN 1 OR 2 CELLS DURING HIGH LOADS

(STARTING OR STARTING TEST)

Possible cause

Remedy

-

Defective cells

Replace battery

-

Leaking partition

Replace battery

FAULT: BATTERY DISCHARGES QUICKLY (CANNOT CONTAIN ITS CHARGE)

Possible cause

Remedy

-

Insufficient charge

Check charge, is charging time (driving time)
sufficient?

-

Short circuit in the charging circuit

Check charging circuit

-

Major self-discharging, e.g. because of
contamination

Clean battery

-

Battery sulphated (on inspection, plates
prove hard and possibly have white
appearance)

Replace battery