TEST

ACTION

APPLICABILITY

3

Remove the power liftgate motor trim panel.
Disconnect the Power Liftgate Module C2 connector.
Disconnect the License Lamp (light bar) connector.
Measure the resistance of the liftgate Temperature Sensor Signal circuit between the
License Lamp connector and the PLG C2 connector.
Is the resistance below 5.0 ohms?

All

Yes

→ Go To 4

No

→ Repair the Liftgate Temperature Sensor Signal circuit for an

open.
Perform BODY VERIFICATION TEST - VER 1.

4

Remove the power liftgate motor trim panel.
Disconnect the Power Liftgate Module C2 connector.
Disconnect the License Lamp (light bar) connector.
Measure the resistance of the Ground circuit between the PLG C2 connector (cavity
20) and the License Lamp connector (cavity 8).
Is the resistance below 5.0 ohms

All

Yes

→ Go To 5

No

→ Repair the Liftgate Temperature Sensor Ground wire for an open.

Perform BODY VERIFICATION TEST - VER 1.

5

If there are no possible causes remaining, view repair.

All

Repair

Replace the Liftgate Temperature Sensor (light bar).
Perform BODY VERIFICATION TEST - VER 1.

957

POWER DOORS - LIFTGATE

AMBIENT TEMPERATURE SENSOR CIRCUIT OPEN —

Continued

Symptom:

AMBIENT TEMPERATURE SENSOR CIRCUIT SHORT TO GROUND

When Monitored and Set Condition:

AMBIENT TEMPERATURE SENSOR CIRCUIT SHORT TO GROUND

When Monitored:

Whenever the Power Liftgate Module is awake.

Set Condition:

If the module senses a resistance below 1000 ohms on the Liftgate

Temperature Sensor Signal circuit, this code will set. The normal range for the sensor is
1.2K to 382K ohms. At room temperature (68° F) the resistance will be between 11.2 K and
13.5K ohms.

POSSIBLE CAUSES

DTC PRESENT

LIFTGATE TEMPERATURE SENSOR SIGNAL CIRCUIT SHORT TO GROUND.

POWER LIFTGATE MODULE - TEMP SENSE SHORT TO GROUND

LIFTGATE TEMPERATURE SENSOR SIGNAL WIRE SHORT TO GROUND WIRE

LIFTGATE TEMPERATURE SENSOR

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, record and erase DTC’s.

Turn the ignition off, wait 10 seconds, then turn the ignition on.
Operate the liftgate several times.
With the DRBIII

t, read DTCs.

Does the DRBIII

t display AMBIENT TEMPERATURE SENSOR CIRCUIT SHORT

TO GROUND?

All

Yes

→ Go To 2

No

→ Using the wiring diagram/schematic as a guide, inspect the

wiring and connectors for an intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.

2

Remove the power liftgate motor trim panel.
Disconnect the Power Liftgate Module C2 connector.
Measure the resistance between ground and the liftgate Temperature Sensor Signal
circuit.
Is the resistance below 5000.0 ohms?

All

Yes

→ Repair the Liftgate Temperature Sensor Signal circuit for a short

to ground.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

958

POWER DOORS - LIFTGATE

TEST

ACTION

APPLICABILITY

3

Remove the power liftgate motor trim panel.
Disconnect the Power Liftgate Module C2 connector.
Measure the resistance of the liftgate Temperature Sensor Signal circuit to the
Ground circuit (cavity 20) in the PLG C2 connector.
Is the resistance below 1000.0 ohms?

All

Yes

→ Go To 4

No

→ Replace the Power Liftgate Module.

Perform BODY VERIFICATION TEST - VER 1.

4

Remove the power liftgate motor trim panel.
Disconnect the Power Liftgate Module C2 connector.
Disconnect the License Lamp (light bar) connector.
Measure the resistance of the liftgate Temperature Sensor Signal circuit to the
Ground circuit (cavity 20) in the PLG C2 connector.
Is the resistance below 1000.0 ohms

All

Yes

→ Repair the Liftgate Temperature Sensor Signal wire for a short to

the Ground wire.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Liftgate Temperature Sensor (light bar).

Perform BODY VERIFICATION TEST - VER 1.

959

POWER DOORS - LIFTGATE

AMBIENT TEMPERATURE SENSOR CIRCUIT SHORT TO GROUND —

Continued

Symptom:

CONTROL MODULE FAILURE - INTERNAL FAILURE

When Monitored and Set Condition:

CONTROL MODULE FAILURE - INTERNAL FAILURE

When Monitored:

Anytime the module is awake.

Set Condition:

Whenever the module senses an internal failure (EEPROM, ROM, ADC)

this code will set. The module must be replaced.

POSSIBLE CAUSES

POWER LIFTGATE MODULE - INTERNAL FAILURE

TEST

ACTION

APPLICABILITY

1

View repair.

All

Repair

Replace the Power Liftgate Module.
Perform BODY VERIFICATION TEST - VER 1.

960

POWER DOORS - LIFTGATE

 

 

 

 

 

 

 