FRONT IR SENSOR HIGH (STORED) When Monitored: With the ignition on and the IOD fuse installed. Set Condition: This DTC is set if the ATC reads the Front IR Sensor value and it is above 250 A/D counts. FRONT IR SENSOR LOW (STORED) When Monitored: With the ignition on and the IOD fuse installed. Set Condition: This DTC is set if the ATC reads the Front IR Sensor value and it is below 5 A/D counts. FRONT IR SENSOR NOT CALIBRATED (STORED) When Monitored: With the ignition on and the IOD fuse installed. Set Condition: This DTC is set if the ATC cannot read the IR sensor values or the IR sensor values are not within a defined range of the HVAC air door motor counts. FRONT KEYBOARD COMMUNICATION FAULT (STORED) When Monitored: With the ignition on and the IOD fuse installed. Set Condition: This DTC will set if there is an internal fault in the ATC head. FRONT KEYBOARD FAULT (STORED) When Monitored: With the ignition on and the IOD fuse installed. Set Condition: This DTC will set if there is an internal fault in the ATC head. FRONT MODE DOOR NOT RESPONDING (STORED) When Monitored: With the ignition on and the IOD fuse installed. Set Condition: This DTC is set if the ATC does not receive feedback pulses within 5 seconds of the drive voltage being applied. FRONT MODE DOOR TRAVEL TOO LARGE (STORED) When Monitored: With the ignition on and the IOD fuse installed. Set Condition: This DTC is set when the ATC monitors the travel range during system initialization and the measured range is greater than expected. FRONT MODE DOOR TRAVEL TOO SMALL (STORED) When Monitored: With the ignition on and the IOD fuse installed. Set Condition: This DTC is set when the ATC monitors the travel range during system initialization and the measured range is less than expected. PASS BLEND DOOR NOT RESPONDING (STORED) When Monitored: With the ignition on and the IOD fuse installed. Set Condition: This DTC is set if the ATC does not receive feedback pulses within 5 seconds of the drive voltage being applied. 325 AUTOMATIC TEMPERATURE CONTROL AC PRESSURE TOO HIGH (STORED) — Continued |