Chrysler PT Cruiser. Manual - part 72

 

  Index      Chrysler     Chrysler PT Cruiser - service repair manual 2005 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  70  71  72  73   ..

 

 

Chrysler PT Cruiser. Manual - part 72

 

 

Symptom:

*DRIVER DOOR FAILS UNLOCK - PT27

POSSIBLE CAUSES

DRIVER DOOR UNLOCK RELAY OUTPUT CIRCUIT SHORT TO GROUND

REMOTE KEYLESS ENTRY MODULE - DRIVER UNLOCK RELAY

TEST

ACTION

APPLICABILITY

1

Turn the ignition off.
Disconnect the Remote Keyless Entry module connector.
Measure the resistance between ground and the Driver Door Unlock Relay Output
circuit.
Is the resistance below 5000.0 ohms?

All

Yes

→ Repair the Driver Door Unlock Relay Output circuit for a short to

ground.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Remote Keyless Entry Module.

Perform BODY VERIFICATION TEST - VER 1.

275

POWER DOOR LOCKS/RKE

Symptom:

*LIFTGATE LOCK MOTOR FAILS TO LOCK OR UNLOCK

POSSIBLE CAUSES

LIFTGATE LOCK MOTOR

DOOR UNLOCK RELAY OUTPUT WIRE OPEN

DOOR UNLOCK RELAY OUTPUT WIRE SHORT TO GROUND

DOOR LOCK RELAY OUTPUT WIRE OPEN

DOOR UNLOCK RELAY OUTPUT SHORT TO DOOR LOCK RELAY OUTPUT

DOOR LOCK RELAY OUTPUT WIRE SHORT TO GROUND

TEST

ACTION

APPLICABILITY

1

Remove the liftgate trim panel to gain access to the Liftgate Lock Motor connector.
Disconnect the Liftgate Lock Motor connector.
Connect a test light between the Door Lock Relay Output and the Door Unlock Relay
Output circuits in the liftgate lock motor connector.
Press the door lock switch to the Lock and Unlock positions.
Did the test light illuminate when the lock switch was pressed in both directions?

All

Yes

→ Replace the Liftgate Lock Motor.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 2

2

Turn ignition off.
Remove the liftgate trim panel to gain access to the Liftgate Lock Motor connector.
Disconnect the Liftgate Lock Motor connector.
Using a 12-volt test light connected to ground, check the Door Unlock Relay Output
circuit.
With the DRBIII

t, actuate the door unlock relay and observe the test light.

Does the test light illuminate brightly when the relay is actuated?

All

Yes

→ Go To 3

No

→ Repair the Door Unlock Relay Output wire for an open.

Perform BODY VERIFICATION TEST - VER 1.

3

Turn ignition off.
Remove the liftgate trim panel to gain access to the Liftgate Lock Motor connector.
Disconnect the Liftgate Lock Motor connector.
Disconnect the Remote Keyless Entry module connector.
Measure the resistance of the Door Unlock Relay Output wire to ground.
Is the resistance below 1000.0 ohms?

All

Yes

→ Repair the Door Unlock Relay Output wire for a short to ground.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 4

276

POWER DOOR LOCKS/RKE

TEST

ACTION

APPLICABILITY

4

Turn ignition off.
Remove the liftgate trim panel to gain access to the Liftgate Lock Motor connector.
Disconnect the Liftgate Lock Motor connector.
Using a 12-volt test light connected to ground, check the Door Lock Relay Output
circuit.
With the DRBIII

t, actuate the Door Lock Relay and observe the test light.

Does the test light illuminate brightly when the relay is actuated?

All

Yes

→ Go To 5

No

→ Repair the Door Lock Relay Output wire for an open.

Perform BODY VERIFICATION TEST - VER 1.

5

Turn ignition off.
Remove the liftgate trim panel to gain access to the Liftgate Lock Motor connector.
Disconnect the Liftgate Lock Motor connector.
Disconnect the Remote Keyless Entry module connector.
Measure the resistance between the Door Unlock Relay Output circuit and the Door
Lock Relay Output circuit
Is the resistance below 1000.0 ohms?

All

Yes

→ Repair the Door Unlock Relay Output wire for a short to the Door

Lock Relay Output wire.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 6

6

Turn ignition off.
Remove the liftgate trim panel to gain access to the Liftgate Lock Motor connector.
Disconnect the Liftgate Lock Motor connector.
Disconnect the Remote Keyless Entry module connector.
Measure the resistance of the Door Lock Relay Output wire to ground.
Is the resistance below 1000.0 ohms?

All

Yes

→ Repair the Door Lock Relay Output wire for a short to ground.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Test Complete.

277

POWER DOOR LOCKS/RKE

*LIFTGATE LOCK MOTOR FAILS TO LOCK OR UNLOCK —

Continued

Symptom:

*ONE DOOR FAILS TO LOCK AND UNLOCK - PT27

POSSIBLE CAUSES

*OPEN MOTOR - 27

DOOR (OR DRIVER DOOR) UNLOCK RELAY OUTPUT WIRE OPEN

DOOR LOCK RELAY OUTPUT WIRE OPEN

DOOR (OR DRIVER DOOR) UNLOCK RELAY OUTPUT CKT SHORT TO DOOR LOCK RELAY OUT-
PUT

RKE MODULE - DOOR LOCK OPEN

RKE MODULE - DOOR UNLOCK OPEN

RKE MODULE - SHORTED

TEST

ACTION

APPLICABILITY

1

Disconnect the inoperative Door Lock Motor/Ajar Switch connector.
Using a 12-volt test light, connect one end to the Door Lock Relay Output ckt and the
other to the Door (or Driver Door ) Unlock Relay Output ckt.
With the DRBIII

t, actuate the Door Lock Relay and then the Door (or Drv Door)

Unlock Relay and observe the test light..
Did the test light illuminate brightly when the switch was activated in both
directions?

All

Yes

→ Replace the Door Lock Motor.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 2

2

Disconnect the inoperative Door Lock Motor/Ajar Switch.
Using a 12-volt test light connected to ground, check the Door Lock Relay Output
circuit.
With the DRBIII

t, actuate the Door Lock Relay and observe the test light.

Does the test light illuminate brightly when the relay is actuated?

All

Yes

→ Go To 3

No

→ Go To 6

3

Disconnect the inoperative Door Lock Motor/Ajar Switch.
Using a 12-volt test light connected to ground, check the Door (or Driver Door)
Unlock Relay Output circuit.
With the DRBIII

t, actuate the appropriate Door Unlock Relay and observe the test

light.
Does the test light illuminate brightly when the relay is actuated?

All

Yes

→ Go To 4

No

→ Go To 5

278

POWER DOOR LOCKS/RKE

 

 

 

 

 

 

 

Content   ..  70  71  72  73   ..