Symptom: EVIC SWITCH INPUT CIRCUIT OPEN When Monitored and Set Condition: EVIC SWITCH INPUT CIRCUIT OPEN When Monitored: The MIC power-up diagnostics will test the EVIC Button A/D port for either an open circuit, short to power or ground, or a stuck button exists. Set Condition: The Instrument Cluster detects no feedback on the EVIC Switch Sense circuit for 2 seconds. POSSIBLE CAUSES EVIC SWITCH SENSE CIRCUIT OPEN EVIC/NAV SWITCH SENSE RETURN CIRCUIT OPEN CLOCK MODULE INSTRUMENT CLUSTER TEST ACTION APPLICABILITY 1 Turn the ignition off. All Yes → Repair the EVIC/NAV Switch Sense Return circuit for an open. Perform BODY VERIFICATION TEST - VER 1. No → Go To 2 2 Turn the ignition off. All Yes → Replace the Clock Module in accordance with the Service Infor- mation. No → Go To 3 709 INSTRUMENT CLUSTER |