TEST
ACTION
APPLICABILITY
3
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and
black test probes.
Connect the scope input cable to the channel one connector on the DRB. Attach the
red and black leads and the cable to probe adapter to the scope input cable.
With the DRBIII
t select Pep Module Tools.
Select lab scope.
Select Live Data.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again
when complete.
Disconnect the CD/DVD Changer harness connector.
Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus
circuit in the CD/DVD Changer connector.
Reconnect the Radio C2 harness connector.
Turn the ignition on.
Turn the Radio and CD/DVD Changer on.
Observe the voltage display on the DRB Lab Scope.
Does the voltage pulse from 0 to approximately 7.5 volts?
All
Yes
→ Go To 4
No
→ Replace the Radio.
Perform BODY VERIFICATION TEST - VER 1.
4
Turn the ignition off.
Disconnect the CD/DVD Changer harness connector.
Turn the ignition on.
Turn the Radio and the CD/DVD Changer on.
Using a 12-volt test light connected to ground, probe the Ignition RUN/ACC Signal
circuit.
Is the test light illuminated?
All
Yes
→ Go To 5
No
→ Replace the Radio.
Perform BODY VERIFICATION TEST - VER 1.
5
Turn the ignition off.
Disconnect the CD/DVD Changer harness connector.
Using a 12-volt test light connected to 12-volts, probe the ground circuit.
Is the test light illuminated?
All
Yes
→ Replace the CD/DVD Changer in accordance with the service
information
Perform BODY VERIFICATION TEST - VER 1.
No
→ Repair the ground circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
309
AUDIO
NO COMMUNICATION WITH CD/DVD CHANGER - RADIO —
Continued