06– 42 06 a. Turn ignition switch to LOCK. connector E-076. d. Check wire harness between downstream oxygen sensor connector terminals and engine compartment fuse and Check for Short 4 Check downstream oxygen sensor power supply circuit E-076 E-043 1 2 3 4 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 - + RT21065012 Multimeter Connection Condition Specified Condition E-043 (4) - E-076 (A7) Always Continuity Multimeter Connection Condition Specified Condition E-043 (4) or E-076 (A7) - Body ground Always No continuity E-043 (4) or E-076 (A7) - Battery positive Always No continuity Replace fuse, main relay, wire harness or NG OK |