Chery S11 / Chery QQ. Manual - part 76

 

 

   Chery QQ Service Manual 

Improperly wiring in the circuit 

Over damp system 

Check the expansion valve 

Repair if necessary 

evacuate and charge the 

system 

cold air exists only at high 

speed 

Condensator is blocked 

Drive belt trackslip 

Compressor fault 

Insufficient or over-charged 

refrigerant  

Air exists in the system 

Check the condensator 

Check or replace the drive 

belt 

Check the compressor 

Check the refrigerant charge

Evacuate and charge the 

system with refrigerant 

 
 
 
 

 

Insufficient refrigeration 

 

 

 

Condensator is blocked 

Drive belt trackslip 

Electric magnetic clutch fault   

Compressor fault 

Expansion valve fault   

Thermistor fault 

Insufficient or over-charged 

refrigerant  

Air exists in the system or excessive 

oil in the compressor 

Stock solution drier is blocked   

Check the condensator 

Check or replace the drive 

belt 

Check the electric magnetic 

clutch 

Check the compressor 

Check the expansion valve 

Check the thermistor 

Check refrigerant charge 

Evacuate and charge the 

system 

Check the stock solution 

drier 

Insufficient flow speed of 

cold air 

Evaporator is blocked or frosts 

Air leakage in the cooling device or 

air ducts 

Air inlet is blocked 

Air blower motor fault 

Check the evaporator 

Repair if necessory 

Repair if necessory 

Replace the air blower 

motor 

 

II Trouble-shooting Chartelectron temperature control system 

143

   Chery QQ Service Manual 

Phenomenon 

Possible position 

of the fault   

Diagnosis and 

measurement 

Result Reason 

power source is 

out of condition 

F6 ( 20A ) fuse 

voltage 12V 

F6 is out of 

condition 

Without air conditioner 

relay power source 

air conditioner 

relay is out of 

conditon 

  No.  30,  87  pin 

voltates for relay 

operation are 12V   

Relay is out of 

condition 

Contacts is out of 

condition 

Air blower 
switch

 

Air blower switch 

disconnects the 

no.2 pin ground 

strap connection 

Air blower switch 

is out of condition 

or no.1 pin does not 

ground 

Without ground strap 

connection signal 

output 

A/C switch 

A/C switch on no.1 

pin 

 

A/C switch or 

compression is out 

of condition 

Without ground strap 

connection signal 

output 

pressure switch is 

out of condition 

Remove the joint,

 

direct

 

cross 

connection   

Switch is out of 

condition or 

insufficient 

pressure 

Pressure switch can not 

be turned on 

temperature 

sensor for 

evaporator is out 

of condition   

Resistance value is 

over 2KΩ 

Sensor is out of 

condition or 

improper 

installation 

Detection  temperature 

is too low 

water temperature 

for engine is too 

low 

Check the engine 

values 

water temperature 

sensor is out of 

condition 

water temperature is too 

low , compressor does 

not work 

The engine is 

accelerating 

Gasoline throttle 

position sensor 

normal normal 

operation 

conditions 

The 

compressor 

does not work 

when the air 

conditioner 

switch is 

turned on 

ECU is out of 

condition 

Measure the ECU 

no.41, 22 pins 

ECU or wiring 

ECU  cannot  deal  with 

the A/C swich signals 

 
 

Air blower 

does not 

duty relay is out 

of condition 

No.85, 86, 30, 87 

pins of the relay 

Wiring is out of 

condition 

Without +12V supplied 

to air blower 

144

   Chery QQ Service Manual 

resistance of air 

blower is out of 

condition 

Measuring 

resistance is over 

0Ω 

Resistance is short 

circuit 

Without speed governing 

signal 

Switch of air 

blower is out of 

condition 

Measuring switch 

conduction 

Switch is out of 

condition 

Without control signal 

work 

air blower is out 

of condition 

Remove plug ,

power supply 12V 

Air blower breaks 

down 

replace 

F2 fuse 

+12V 

Break down 

replace 

High speed fan 

relay 

measure the relay 

and the wiring 

replace 

Without +12V supplied 

to heat emission fan 

fan wiring is out 

of condition 

pin measurement 

repair 

connection of the pins or 

wiring is out of 

condition 

air blower is out 

of condition 

Remove the plug 

and test with power

replace 

Air blower burns out 

water temperature 

sensor is out of 

condition 

Check water 

temperature for 

engine 

replace Low 

water 

temperature 

for  engine 

Pressure switch 

Remove  the  plug, 

cross connection 

insufficient pressure 

of the pressure 

switch or pressure 

Without switch signals 

Fan does not 

work  (high 

speed) 

ECU ECU 

no.31pin 

ground strap 

connection 

ECU is out of 

condition 

replace 

insufficient 

refrigeration 

clutch 

unmovable) 

Refer to the 

diagonosis 

tables metioned 

above(reasons 

out of the 

electron 

temperature 

control system) 

 

 

 

 

145

   Chery QQ Service Manual 

 

Section 9 Maintenance On-board 

 

Note: you should comply with the following rules when maintaining air conditioning 

system. 

1. Wiring 

1)remove the accumulator’s negative wire to avoid short circuit. 

2)the lead connector should be plugged fixedly. 

3) the gum cover should be fitted in panel holes before wiring arrangement to 

protect the wiring bundle. 

4)connect the wiring bundle of air conditioner to main wiring bundle with 

pdythene belt or original binding terminal block. 

5)if original wiring bundle is removed or stripped when maintaining, you should 

put it back to the place where it was. 

6)original binding terminal block and wiring bundle of the air conditioner should 

not be pressed during installation. 

7)when the leads are welded to the wiring bundle, the two leads should have the 

same diameters and the connection should be wrapped with insulated belt. 

8)the wiring bundle should keep away from the  moving elements or high

 

temperature places. 

9)it is not allowed that the connection parts is close to the fuel pipe. 

10)check the wiring bundle if it contacts with sharp edges and corners. 

2. Refrigerating 

return pipe

 

1)heating

 elbow bend pipe is absolutely

 impermissible。 

The degree of bending should be as small as possible. 

2)parts in air conditioner should be kept dry and free of dirt. 

When removing any pipe of the system, you should fit a cap on the joint of this pipe 

as soon as possible. 

3)when the hose and the metal pipe are interconnected, drops of refrigerating oil 