Diagnostic  trouble  code:  P0130  “Malfunction  in  signal  circuit  of  upstream 
oxygen sensor” 

(Note:  The  following  diagnostic  procedures  are  applicable  only  under  the 
circumstances that the trouble code of P0135 does not appear simultaneously, in case 
that such trouble code appears at the same time, overhaul shall be carried out based on 
the following procedures after dealing with the malfunction of P0135 firstly.) 

Item 

No. 

Operation procedure 

Inspection 

results 

Follow-up 

procedure 

Connect  the  diagnostic  tester  and  adaptor, 
and  turn  the  ignition  switch  to  “ON” 
position. 

 

Proceed to next 

step. 

Yes 

Refer to diagnosis 

help. 

Start  up  the  engine,  run  at  idle  speed  until 
the  temperature  of  coolant  reaches  the 
normal  value.  Observe  the  value  of 
“Oxygen sensor voltage” on the diagnostic 
tester  to  verify  that  the  indicated  value  is 
changed  quickly  within  the  range  of 
100mV – 900mV. 

No 

Proceed to next 

step. 

Yes 

Repair and replace 
the wiring harness. 

Verify  that  the  circuits  between  36#  and 
18# pins of ECU and A# (corresponding to 
grey connecting wire of the oxygen sensor) 
and B# (corresponding to black connecting 
wire  of  the  oxygen  sensor)  pins  of  the 
sensor connector are short to ground. 

No 

Proceed to next 

step. 

Yes 

Carry out service 

based on the 

diagnostic results. 

A. Verify that there is quite serious leakage 
in the air intake system; 
B.  Verify  that there  is  blockage  in  the  fuel 
injector; 
C. Verify that the clearance of spark plug is 
excessive large; 
D.  Verify  that  the  resistance  of  distributor 
circuit is excessive large; 
E. Verify that the air intake valve conduit is 
worn out; 
And etc. 

No 

Refer to diagnosis 

help. 

 
 
 
 
 
 
 
 

 

 

Diagnostic  trouble  code:  P0132  “Overvoltage  of  circuit  for  upstream  oxygen 
sensor” 

(Note:  the  following  diagnostic  procedures  are  applicable  only  under  the 
circumstances that the trouble code of P0135 does not appear simultaneously, in case 
that such trouble code appears at the same time overhaul shall be carried out based on 
the following procedures after dealing with the malfunction of P0135 firstly.) 

 

Item 

No. 

Operation procedure 

Inspection 

results 

Follow-up 

procedure 

Connect the diagnostic tester and adaptor, 
and  turn  the  ignition  switch  to  “ON” 
position. 

 

Proceed to next 

step. 

Yes 

Refer to diagnosis 

help. 

Start up the engine, run at idle speed until 
the  temperature  of  coolant  reaches  the 
normal  value.  Observe  the  value  of 
“Oxygen  sensor  voltage”  on  the 
diagnostic  tester  to  verify  that  the 
indicated value  is changed quickly within 
the range of 100mV – 900mV. 

No 

Proceed to next 

step. 

Yes 

Repair and replace 

the wiring harness. 

Verify  that  the  circuits  between  36#  and 
18#  pins  of  ECU  and  A#  (corresponding 
to  grey  connecting  wire  of  the  oxygen 
sensor)  and  B#  (corresponding  to  black 
connecting  wire  of  the  oxygen  sensor) 
pins  of  the  sensor  connector  are  short  to 
power supply. 

No 

Refer to diagnosis 

help. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Diagnostic trouble code: P0134 “Signal malfunction of upstream oxygen sensor” 

(Note:  The  following  diagnostic  procedures  are  applicable  only  under  the 
circumstances that the trouble code of P0135 does not appear simultaneously, in case 
that such trouble code appears at the same time, overhaul shall be carried out based on 
the following procedures after dealing with the malfunction of P0135 firstly.) 

 

Item 

No. 

Operation procedure 

Inspection 

results 

Follow-up 

procedure 

Connect  the  diagnostic  tester  and  adaptor, 
and  turn  the  ignition  switch  to  “ON” 
position. 

 

Proceed to next 

step. 

Yes 

Refer to diagnosis 

help. 

Start  up  the  engine,  run  at  idle  speed  until 
the  temperature  of  coolant  reaches  the 
normal  value.  Observe  the  value  of 
“Oxygen sensor voltage” on the diagnostic 
tester  to  verify  that  the  indicated  value  is 
changed  quickly  within  the  range  of 
100mV – 900mV. 

No 

Proceed to next 

step. 

Yes 

Repair and replace 

the wiring 

harness. 

Verify  that  the  circuits  between  36#  and 
18# pins of ECU and A# (corresponding to 
the grey connecting wire of oxygen sensor) 
and  B#  (corresponding  to  the  black 
connecting  wire  of  oxygen  sensor)  pins  of 
the sensor connector are open. 

No 

Refer to diagnosis 

help. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diagnostic  trouble  code:  P0135  “Malfunction  in  heating  circuit  of  upstream 
oxygen sensor” 

Item 

No. 

Operation procedure 

Inspection 

results 

Follow-up 

procedure 

Connect the diagnostic tester and adaptor, 
and  turn  the  ignition  switch  to  “ON” 
position. 

 

Proceed to next 

step. 

Yes 

Proceed to next 

step. 

Disconnect  the  connector  of  the  oxygen 
sensor  on  the  wiring  harness  and  inspect 
with  multimeter to  verify  that the  voltage 
between  C#  (corresponding  to  the  white 
connecting  wire  of  the  oxygen  sensor) 
and  D#  (corresponding  to  the  white 
connecting  wire  of  the  oxygen  sensor) 
pins of this connector is about 12V. 

No 

Proceed to Step4 

Yes 

Proceed to next 

step. 

Inspect  with  multimeter to  verify  that the 
resistance  between  C#  (white)  and  D# 
(white)  pins  of  the  oxygen  sensor  is 
within 1~6Ω under 20

.

℃  

No 

Replace the sensor. 

Yes 

Replace the fuse. 

Verify  that  the  8A  fuse  in  heating  circuit 
of the oxygen sensor is burn out. 

No 

Proceed to next 

step. 

Yes 

Repair and replace 
the wiring harness. 

Verify  that  the  circuits  between 1#  pin of 
ECU,  87#  pin  of  the  main  relay  and  C# 
(corresponding  to  white  connecting  wire 
of 

the 

oxygen 

sensor) 

and 

D# 

(corresponding  to  white  connecting  wire 
of the oxygen sensor) are open or short to 
ground or power supply. 

No 

Refer to diagnosis 

help. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

Content   ..  11  12  13  14   ..