Acura / Honda transmission. Manual - part 16

 

  Index      Acura     Acura / Honda Automotive Transmission - manual 2011 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  14  15  16  17   ..

 

 

Acura / Honda transmission. Manual - part 16

 

 

The Honda/Acura TCC Solenoid for the B7TA/B7YA can be either an 
ON/OFF or Pulse-Width Modulated unit. The unit is pulsed steadily 
(Fixed Frequency) at 65 to 200 Hz. Then the positive or negative side 
of the wave is widened or narrowed to control the TCC pressure. The 
Pulse-Width has a duty-cycle in percentage. 90% DC = full operation 
10% = almost OFF. Use a duty-cycle meter to test signal. DO NOT 
apply steady power to this unit. This is a low resistance unit and will 
get damaged by steady power application. Use a turn-signal flasher in 
series with the solenoid to test. This will reduce current allowing you to 
test the unit. This unit is POWER controlled by the TCM or PCM at pin 
2. The GROUND is taken from the solenoid body itself. 

TCC PWM Resistance = 15 to 28 Ohms

MAX CURRENT = Do not apply steady power. Low resistance unit.

Electronic Pressure Control Solenoid

The Electronic Pressure Control Solenoid (Solenoid A) for the 
B7TA/B7YA transmission is a PWM or Pulse Width Modulated unit. PWM 
is a ratio of On to OFF. A 90% Duty-Cycle means that the unit is ON 
90% of the time, therefore, there will be high trans-fluid pressure. The 
TCM provides both POWER and GROUND to control the unit. The TCM 
varies the duty-cycle to the solenoid at a steady frequency. Do not 
apply steady power to this solenoid or damage will result. This is a low 
resistance unit. Use a turn-signal flasher in series with the unit when 
testing. This will pulse and restrict power, preventing damage. 

EPC RESISTANCE: 4 to 6 Ohms 

MAX CURRENT: Do not apply steady power. Current depends on duty-
cycle.

BAXA 

Shift Solenoids

The BAXA 3 shift solenoids are normally closed. These solenoids are 
POWER controlled through independent sol. connectors pin 2 each. The 
solenoid wires are GROUNDED at the transmission body itself. Solenoid 
resistance should be between 11 and 26 Ohms. TO meassure voltage, 
inject power at sol. pins. You should see 12 volts at sol. body when 
solenoid is removed from trans-body and hear a click. If no voltage is 
seen at solenoid body side, then solenoid coil is open or broken. 

SHIFT-SOLENOID Resistance = 11 - 26 Ohms

MAXIMUM CURRENT at room temperature = 1.10 Amps or 1100 mA

POWER FEED Test between Batt + and Solenoid Power-Feed = 100 to 
300 mVolts w/KOER

TCC On/Off solenoid

The BAXA TCC On/Off solenoid is used to control the application of the 
torque converter wet clutches. This is just an Allow or Not-allow 
device. Once the TCC On/Off solenoids allows fluid passage, the TCC 
PWM solenoid then controls the engagement and makes actuation 
harsher or softer. The TCC On/Off solenoid is very similar electrically 
and often the same as the normal shift solenoids. This solenoid is 
POWER controlled by the TCM at pin 1 (yel). The TCC solenoid is 
grounded at the body or dedicated ground wire. A TCC PWM may also 
be employed called Sol-B. If power is applied, you'll hear a click. Also 
remove the solenoid and see if when injecting power the solenoid body 
also goes to 12 volt potential, indicating good solenoid-coil integrity. 

TCC On/Off Resistance = 12 - 24 Ohms

MAXIMUM CURRENT at room temperature = 1.00 Amps or 1000 mA

POWER FEED Test between Batt + and Solenoid Power-Feed = 100 to 
300 mVolts w/KOER

TCC PWM Solenoid

The Honda/Acura TCC Solenoid for the BAXA can be either an ON/OFF 
or Pulse-Width Modulated unit. The unit is pulsed steadily (Fixed 
Frequency) at 65 to 200 Hz. Then the positive or negative side of the 

wave is widened or narrowed to control the TCC pressure. The Pulse-
Width has a duty-cycle in percentage. 90% DC = full operation 10% = 
almost OFF. Use a duty-cycle meter to test signal. DO NOT apply 
steady power to this unit. This is a low resistance unit and will get 
damaged by steady power application. Use a turn-signal flasher in 
series with the solenoid to test. This will reduce current allowing you to 
test the unit. This unit is POWER controlled by the TCM or PCM at pin 
2. The GROUND is taken from the solenoid body itself. 

TCC PWM Resistance = 15 to 28 Ohms

MAX CURRENT = Do not apply steady power. Low resistance unit.

Electronic Pressure Control Solenoid (Solenoid A)

The Electronic Pressure Control Solenoid (Solenoid A) for the BAXA 
transmission is a PWM or Pulse Width Modulated unit. PWM is a ratio of 
On to OFF. A 90% Duty-Cycle means that the unit is ON 90% of the 
time, therefore, there will be high trans-fluid pressure. The TCM 
provides both POWER and GROUND to control the unit. The TCM varies 
the duty-cycle to the solenoid at a steady frequency. Do not apply 
steady power to this solenoid or damage will result. This is a low 
resistance unit. Use a turn-signal flasher in series with the unit when 
testing. This will pulse and restrict power, preventing damage. 

EPC RESISTANCE: 4 to 6 Ohms 

MAX CURRENT: Do not apply steady power. Current depends on duty-
cycle.

BGRA 

Shift Solenoids

The BGRA 4 shift solenoids are normally closed. These solenoids are 
POWER controlled at trans conn. pins 5(SS-A [Blu/Blk]), 2(SS-B [Grn/
Wht]), 1(SS-C [Grn]) and 3(SS-D [Yel]). The solenoid wires are 
GROUNDED at the transmission body itself. Solenoid resistance should 
be between 11 and 26 Ohms. TO meassure voltage, inject power at 
sol. pins. You should see 12 volts at sol. body when solenoid is 
removed from trans-body and hear a click. If no voltage is seen at 
solenoid body side, then solenoid coil is open or broken. 

SHIFT-SOLENOID Resistance = 11 - 26 Ohms

MAXIMUM CURRENT at room temperature = 1.10 Amps or 1100 mA

POWER FEED Test between Batt + and Solenoid Power-Feed = 100 to 
300 mVolts w/KOER

TCC On/Off solenoid

The BGRA TCC On/Off solenoid (Sol-A) is used to control the 
application of the torque converter wet clutches. This is just an Allow 
or Not-allow device. Once the TCC On/Off solenoids allows fluid 
passage, the TCC PWM solenoid then controls the engagement and 
makes actuation harsher or softer. The TCC On/Off solenoid is very 
similar electrically and often the same as the normal shift solenoids. 
This solenoid is POWER controlled by the TCM at pin 1 (yel). The TCC 
solenoid is grounded at the body or dedicated ground wire. A TCC 
PWM may also be employed (Sol B). If power is applied, you'll hear a 
click. Also remove the solenoid and see if when injecting power the 
solenoid body also goes to 12 volt potential, indicating good solenoid-
coil integrity. 

TCC On/Off Resistance = 12 - 24 Ohms

MAXIMUM CURRENT at room temperature = 1.00 Amps or 1000 mA

POWER FEED Test between Batt + and Solenoid Power-Feed = 100 to 
300 mVolts w/KOER

TCC PWM Solenoid

 

 

 

 

 

 

 

Content   ..  14  15  16  17   ..