Case1 (Stop monitor)
Fail Safe
The return pump does not
work correct.
The ABS/ESC functions
are inhibited, reduced
function of the EBD
system.
The ABS/EBD/ESC
warning lamps are
activated.
Open or short of
power supply
circuit (ABS1)
Inoperative HECU
Case2 (Pump run
monitor)
Monitoring Period
The monitor is active if
the pump is switched on
Enable Conditions
A failure is detected if the
pump motor voltage <
(battery voltage - 4.0 V)
for more than 100ms.
Fail Safe
Pressure decrease (outlet
valve) is no longer
possible.
The ABS/ESC functions
are inhibited, reduced
function of the EBD
system.
The ABS/EBD/ESC
warning lamps are
activated.
Monitoring Period
Monitor is always active
in the transition "pump on
--> pump off"
Enable Conditions
After the end of the
actuation of the motor
relay has, the pump motor
is still in motion and is
generating a Voltage
during it's slowdown. The
generated UM is
monitored for a certain
time on high level. The
time depends on the
supply voltage and is in
the range of t = 30 ms to t
= 125 ms. If the slow
down condition isn't met,
the pump is activated
again (see actuation times