15. MEASUREMENT
B-64693EN-1/01
- 2458 - - Parameter
#7 #6 #5 #4 #3 #2 #1 #0 6200
SRE
[Input type] Parameter input
[Data type] Bit path
#6 SRE When a high-speed skip signal is used: 0: The signal is assumed to be input on the rising edge (contact open → close). 1: The signal is assumed to be input on the falling edge (contact close → open).
- Signal High-speed skip status signal HDO0 to HDO7<Fn122>
#7 #6 #5 #4 #3 #2 #1 #0 Fn122
HDO7 HDO6 HDO5 HDO4 HDO3 HDO2 HDO1 HDO0
[Classification] Output signal [Function] This signal informs the PMC of the input status of the high-speed skip signal.
[Output cond.] 1: When the contact of the high-speed skip signal is closed.
(The input voltage is at a low level.) 0: When the contact of the high-speed skip signal is open. (The input voltage is at a high level.)
15.3.4 Continuous High-Speed Skip Function Overview The continuous high-speed skip function enables reading of absolute coordinates by using the high-speed Explanation Custom macro variables Once a high–speed skip signal has been input in a G31P90 block, absolute coordinates are written to System with more than 20 axes #5061 Coordinate along the first axis #100151 Coordinate along the first axis #5062 Coordinate along the second axis #100152 Coordinate along the second axis #5063 Coordinate along the third axis #110153 Coordinate along the third axis :
: #5079 Coordinate along the 19th axis #100181 Coordinate along the 31st axis #5080 Coordinate along the 20th axis #100182 Coordinate along the 32nd axis
|