Toyota FJ Cruiser (GSJ 10, 15 series). Instruction - part 469

 

  Index      Toyota     Toyota FJ Cruiser (model GSJ 10, 15 series) - service repair instruction 2007 year

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

 

Content   ..  467  468  469  470   ..

 

 

Toyota FJ Cruiser (GSJ 10, 15 series). Instruction - part 469

 

 

SERVICE SPECIFICATIONS  –  1GR-FE FUEL

SS–13

SS

TORQUE SPECIFICATIONS

Part Tightened

N*m

kgf*cm

ft.*lbf

Fuel tank band x Body

40

408

30

No. 1 fuel tank protector sub-assembly x Fuel tank band

20

204

15

Fuel tank protector bracket x Body

5.5

56

49 in.*lbf

Fuel delivery pipe sub-assembly x Intake manifold

15

153

11

Intake air surge tank x Intake manifold

28

286

21

Intake air surge tank x Throttle body bracket

21

214

16

Intake air surge tank x No. 1 surge tank stay

21

214

16

Intake air surge tank x No. 2 surge tank stay

21

214

16

Fuel pressure regulator assembly x Fuel delivery pipe sub-assembly

9.0

92

80 in.*lbf

Negative battery terminal

3.9

40

35 in.*lbf

No. 1 surge tank stay x Oil baffle plate

9.0

92

80 in.*lbf

Fuel pump resister x Body

8.5

87

75 in.*lbf

No. 3 fuel tank protector x Fuel tank

5.0

51

44 in.*lbf

SERVICE SPECIFICATIONS  –  1GR-FE EMISSION CONTROL

SS–13

SS

1GR-FE EMISSION CONTROL

SERVICE DATA

Air-fuel ratio compensation system

Voltage

Standard

B2 - B22

(A1A+) - B3

- 1 (E1)

3.3 V

B2 - 23

(A2A+) - B3

- 1 (E1)

3.3 V

B2 - 22

(A1A-) - B3

- (E1)

2.9 V

B2 - 31

(A2A-) - B3

- (E1)

2.9 V

Fuel cut off rpm

Cut off

2,500 rpm

Return

1,200 rpm

Lead detection pump

Voltage

Standard

A23 (VC) -

A28 (E2)

4.5 to 5.5 V

E22

(PPMP) -

A28 (E2)

1.425 to 4.150 V

vacuum Switching Valve

Resistance

Standard

1 - Body

10 M

Ω or higher at 20°C (68°F)

2 - Body

10 M

Ω or higher at 20°C (68°F)

Air fuel ratio sensor (Bank 1, Bank 2)

Resistance

Standard

1 (HT) - 2

(+B)

1.8 to 3.4 

Ω at 20°C (68°F)

1 (HT) - 4

(E1)

10 k

Ω or higher

Heated oxygen sensor No. 2 (Bank 1, Bank 
2)

Resistance

Standard

1 (HT) - 2

(+B)

11 to 16 

Ω at 20°C (68°F)

1 (HT) - 4

(E1)

10 k

Ω or higher

SS–14

SERVICE SPECIFICATIONS  –  1GR-FE EMISSION CONTROL

SS

TORQUE SPECIFICATIONS

Part Tightened

N*m

kgf*cm

ft.*lbf

Duty vacuum switching valve x Intake air surge tank

9.0

92

80 in.*lbf

Ventilation valve x Cylinder head cover

27

275

20

Heated oxygen sensor x Exhaust pipe

44

449

33

Air fuel ratio sensor x Exhaust manifold

44

449

33

Negative battery terminal

3.9

40

35 in.*lbf

Charcoal canister x Body

20

204

15

SS–14

SERVICE SPECIFICATIONS  –  1GR-FE INTAKE

SS

1GR-FE INTAKE

SERVICE DATA

No. 1 vacuum switching valve assembly

Resistance

Standard

1 - 2

33 to 39 

Ω at 20°C (68°F)

1 - Body

10 k

Ω or higher

2 - Body

10 k

Ω or higher

 

 

 

 

 

 

 

Content   ..  467  468  469  470   ..