Exhaust pipe (for Regular Cab Standard Deck) EXHAUST PIPE (FOR REGULAR CAB STANDARD DECK) - TORQUE SPECIFICATIONS Exhaust pipe (except Regular Cab Standard Deck) EXHAUST PIPE (EXCEPT REGULAR CAB STANDARD DECK) - TORQUE SPECIFICATIONS 1GR-FE COOLING SERVICE DATA Thermostat THERMOSTAT - SERVICE DATA Radiator cap RADIATOR CAP - SERVICE DATA Fin for blockage FIN FOR BLOCKAGE - SERVICE DATA Control valve shaft x No. 2 intermediate shaft assembly 35 360 26 No. 2 intermediate shaft assembly x Sliding yoke 35 360 26 Part Tightened N*m kgf*cm ft.*lbf Front exhaust pipe x Exhaust manifold RH 54 554 40 Front No. 2 exhaust pipe x Exhaust manifold LH 54 554 40 Front No. 3 exhaust pipe x Front No. 2 exhaust pipe 48 489 35 Center exhaust pipe x Front exhaust pipe and Front No. 3 exhaust pipe 48 489 35 Clamp 32 326 24 Part Tightened N*m kgf*cm ft.*lbf Front exhaust pipe x Exhaust manifold RH 54 554 40 Front No. 2 exhaust pipe x Exhaust manifold LH 54 554 40 Center exhaust pipe x Front exhaust pipe and Front No. 3 exhaust pipe 48 489 35 Clamp 32 326 24 Standard valve opening temperature 80 to 84°C (176 to 183°F) Standard valve lift 8.0 mm (0.315 in.) or more at 95°C (203°F) Standard valve (for brand-new cap) 93 to 122 kPa (0.95 to 1.25 kgf/cm 2 , 13.5 to 18 psi) Minimum standard valve (after using cap) 79 kPa (0.8 kgf/cm 2 , 11.4 psi) 300 mm (11.8 in.) 2942 to 4903 kPa (30.0 to 50.0 kgf/cm 2 , 427 to 711 psi)
2009 Toyota Tundra 2009 GENERAL INFORMATION Service Specifications - Tundra
|