DLK-382 < SYMPTOM DIAGNOSIS > P RANGE INTERLOCK DOOR LOCK/UNLOCK FUNCTION DOES NOT OPER- ATE P RANGE INTERLOCK DOOR LOCK/UNLOCK FUNCTION DOES NOT OP- Diagnosis Procedure INFOID:0000000009649346 1. CHECK “AUTOMATIC LOCK/UNLOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT. 2. Select “AUTOMATIC LOCK/UNLOCK SELECT” in “WORK SUPPORT” mode. 3. Check “AUTOMATIC LOCK/UNLOCK SELECT” setting in “WORK SUPPORT”. DLK-94, "DOOR LOCK : CONSULT Function (BCM - DOOR LOCK)" Is the inspection result normal? YES >> GO TO 2. NO >> Set “Unlock Only”, “Lock Only” or “Lock/Unlock” in “AUTOMATIC LOCK/UNLOCK SELECT”. 2. CHECK “AUTOMATIC DOOR LOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT. 2. Select “AUTOMATIC DOOR LOCK SELECT” in “WORK SUPPORT” mode. 3. Check “AUTOMATIC DOOR LOCK SELECT” setting in “WORK SUPPORT”. DLK-94, "DOOR LOCK : CONSULT Function (BCM - DOOR LOCK)" Is the inspection result normal? YES >> GO TO 3. NO >> Set “P RANGE” in “AUTOMATIC DOOR LOCK SELECT”. 3. CHECK “AUTOMATIC DOOR UNLOCK SELECT” SETTING IN “WORK SUPPORT” 1. Select “DOOR LOCK” of “BCM” using CONSULT. 2. Select “AUTOMATIC DOOR UNLOCK SELECT” in “WORK SUPPORT” mode. 3. Check “AUTOMATIC DOOR UNLOCK SELECT” setting in “WORK SUPPORT”. DLK-94, "DOOR LOCK : CONSULT Function (BCM - DOOR LOCK)" Is the inspection result normal? YES >> GO TO 4. NO >> Set “MODE 2” or “MODE 4” in “AUTOMATIC DOOR UNLOCK SELECT”. 4. REPLACE BCM 1. Replace BCM. Refer to BCS-98, "Removal and Installation" . 2. Confirm the operation after replacement. Is the result normal? YES >> INSPECTION END NO >> Check intermittent incident. Refer to GI-42, "Intermittent Incident" . |