DLK-322 < DTC/CIRCUIT DIAGNOSIS > NEUTRAL SWITCH NEUTRAL SWITCH SLIDING DOOR LH SLIDING DOOR LH : Component Function Check INFOID:0000000009649256 1. CHECK FUNCTION 1. Select “AUTO SLDE DOOR” using CONSULT. 2. Select “NEUTRAL SW” in “DATA MONITOR” mode. 3. Check that the function operates normally according to the following conditions. Is the inspection result normal? YES >> Neutral switch is OK. NO >> Refer to DLK-322, "SLIDING DOOR LH : Diagnosis Procedure" SLIDING DOOR LH : Diagnosis Procedure INFOID:0000000009649257 1. CHECK NEUTRAL SWITCH INPUT SIGNAL 1. Turn ignition switch OFF. 2. Disconnect sliding door lock assembly LH connector. 3. Check voltage between sliding door lock assembly LH harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> GO TO 2. 2. CHECK NEUTRAL SWITCH CIRCUIT 1. Disconnect sliding door control unit LH connector. 2. Check continuity between sliding door control unit LH harness connector and sliding door lock assembly 3. Check continuity between sliding door control unit LH harness connector and ground. Is the inspection result normal? YES >> Replace sliding door control unit LH. Refer to DLK-500, "LH : Removal and Installation" NO >> Repair or replace harness. 3. CHECK NEUTRAL SWITCH GROUND CIRCUIT 1. Disconnect sliding door control unit LH connector. Monitor item Condition Status NEUTRAL SW Sliding door closure mo- Neutral position OFF Other than ON (+) (–) Voltage Sliding door lock assembly LH Connector Terminal D123 6 Ground 8 – 16 V Sliding door control unit LH Sliding door lock assembly LH Continuity Connector Terminal Connector Terminal B45 15 D123 6 Existed Sliding door control unit LH Ground Continuity Connector Terminal B45 15 Not existed |