HIGH-PRESSURE PIPE

HA-35

< REMOVAL AND INSTALLATION >

C

D

E

F

G

H

J

K

L

M

A

B

HA

N

O

P

HIGH-PRESSURE PIPE

Removal and Installation

INFOID:0000000009269758

CAUTION:

Perform oil return operation before each refrigeration system disassembly. However, if a large amount

of refrigerant or oil is detected, do not perform oil return operation. Refer to 

HA-21, "Perform Oil

Return Operation"

.

REMOVAL

1. Remove low-pressure flexible hose. Refer to 

HA-33, "Removal and Installation"

.

2. Disconnect high-pressure pipe from expansion valve.

CAUTION:

Cap or wrap the joint of the A/C piping and expansion valve with suitable material such as vinyl

tape to avoid the entry of air.

3. Remove high-pressure pipe bolt and disconnect high-pressure pipe from the condenser.

CAUTION:

Cap or wrap the joint of the A/C piping and condenser with suitable material such as vinyl tape to

avoid the entry of air.

4. Loosen the clip and remove high-pressure pipe from the vehicle.

INSTALLATION

Installation is in the reverse order of removal.

CAUTION:

• Do not reuse O-rings.

• Apply A/C oil to the O-ring of the high-pressure pipe for installation.

• After charging the A/C refrigerant, check for leaks. Refer to 

HA-17, "Leak Test"

.

HA-36

< REMOVAL AND INSTALLATION >

EXPANSION VALVE

EXPANSION VALVE

Removal and Installation

INFOID:0000000009269759

CAUTION:

Perform oil return operation before each refrigeration system disassembly. However, if a large amount

of refrigerant or oil is detected, do not perform oil return operation. Refer to 

HA-21, "Perform Oil

Return Operation"

.

REMOVAL

1. Use refrigerant collecting equipment (for HFC-134a) to discharge the refrigerant. Refer to 

HA-19, "Recy-

cle Refrigerant"

.

2. Disconnect low-pressure flexible hose from expansion valve. Refer to 

HA-33, "Removal and Installation"

.

3. Remove the air cleaner assembly. Refer to 

EM-25, "Removal and Installation"

.

4. Disconnect high-pressure pipe from expansion valve. Refer to 

HA-35, "Removal and Installation"

.

5. Remove the bolts and the expansion valve.

CAUTION:

Cap or wrap the joint of the evaporator and expansion valve with suitable material such as vinyl

tape to avoid the entry of air.

INSTALLATION

Installation is in the reverse order of removal.

CAUTION:

• Do not reuse O-rings.

• Apply A/C oil to the O-rings of the low-pressure flexible hose and high-pressure pipe for installation.

• After charging A/C refrigerant, check for leaks. Refer to 

HA-17, "Leak Test"

.

LIQUID TANK

HA-37

< REMOVAL AND INSTALLATION >

C

D

E

F

G

H

J

K

L

M

A

B

HA

N

O

P

LIQUID TANK

Removal and Installation of Liquid Tank

INFOID:0000000009269760

The liquid tank is only serviced as part of the condenser and liquid tank assembly. Refer to 

HA-31, "Removal

and Installation"

.

HA-38

< REMOVAL AND INSTALLATION >

REFRIGERANT PRESSURE SENSOR

REFRIGERANT PRESSURE SENSOR

Removal and Installation

INFOID:0000000009269761

CAUTION:

Perform oil return operation before each refrigeration system disassembly. However, if a large amount

of refrigerant or oil is detected, do not perform oil return operation. Refer to 

HA-21, "Perform Oil

Return Operation"

.

REMOVAL

1. Use refrigerant collecting equipment (for HFC-134a) to discharge the refrigerant. Refer to 

HA-19, "Recy-

cle Refrigerant"

.

2. Clean refrigerant pressure sensor and its surrounding area and remove dust and rust from refrigerant

pressure sensor.

CAUTION:

Be sure to clean carefully.

3. Disconnect the harness connector from the refrigerant pressure sensor.
4. Remove the refrigerant pressure sensor.

CAUTION:

• Be careful not to damage liquid tank.

• Be careful not to damage core surface of condenser.

• Cap or wrap the joint of the condenser and liquid tank with suitable material such as vinyl tape to

avoid the entry of air.

INSTALLATION

Installation is in the reverse order of removal.

CAUTION:

• Do not reuse O-rings.

• Apply A/C oil to the O-rings of the high-pressure pipe and refrigerant pressure sensor for installa-

tion.

• After charging the A/C refrigerant, check for leaks. Refer to 

HA-17, "Leak Test"

.

 

 

 

 

 

 

 