P117A AIR FUEL RATIO EC-359 < DTC/CIRCUIT DIAGNOSIS > [HR16DE] C D E F G H I J K L M A EC N P O 1. Reconnect the initial spark plugs. 2. Crank engine for approximately 3 seconds, and recheck whether spark is generated between the spark plug and the grounded portion. Is the inspection result normal? YES >> Check intermittent incident. Refer to GI-45, "Intermittent Incident" . NO >> Replace spark plug(s) with standard type one(s). For spark plug type, refer to . Spark should be generated. |