P0451 EVAP CONTROL SYSTEM PRESSURE SENSOR EC-307 < DTC/CIRCUIT DIAGNOSIS > [HR16DE] C D E F G H I J K L M A EC N P O 1. Turn ignition switch OFF. 2. Disconnect ECM harness connector. 3. Check the continuity between EVAP control system pressure sensor harness connector and ECM har- ness connector. 4. Also check harness for short to power. YES >> GO TO 7. NO >> Repair or replace error-detected parts. 7. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR SIGNAL CIRCUIT 1. Check the continuity between EVAP control system pressure sensor harness connector and ECM har- ness connector. 2. Also check harness for short to ground and to power. YES >> GO TO 8. NO >> Repair or replace error-detected parts. 8. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR Check the EVAP control system pressure sensor. Refer to EC-307, "Component Inspection" Is the inspection result normal? YES >> Check intermittent incident. Refer to GI-45, "Intermittent Incident" . NO >> Replace EVAP control system pressure sensor. Refer to FL-16, "Removal and Installation" . Component Inspection INFOID:0000000009267186 1. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR 1. Turn ignition switch OFF. 2. Remove EVAP control system pressure sensor with its harness connector connected from EVAP canister. Always replace O-ring with a new one. 3. Install a vacuum pump to EVAP control system pressure sensor. 4. Turn ignition switch ON and check output voltage between ECM harness connector and ground under the following conditions. CAUTION: • Always calibrate the vacuum pump gauge when using it. 2 , -13.53 psi) or pressure over 101.3 kPa (1.033 kg/ cm 2 , 14.69 psi). Is the inspection result normal? YES >> INSPECTION END NO >> Replace EVAP control system pressure sensor. Refer to FL-16, "Removal and Installation" . EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B3 1 F11 68 Existed EVAP control system pressure sensor ECM Continuity Connector Terminal Connector Terminal B3 2 F11 43 Existed ECM Condition [Applied vacuum kPa (kg/cm 2 , psi)] Voltage Connector + − Terminal F11 43 68 Not applied 0.5 - 4.6 V -26.7 (-0.272, -3.87) 2.1 to 2.5 V lower than above value |