DLK-106 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] TRUNK LAMP SWITCH Is the inspection result normal? YES >> GO TO 3 NO >> Repair or replace harness between BCM and trunk room lamp switch. 3. CHECK TRUNK ROOM LAMP SWITCH GROUND CIRCUIT Check continuity between trunk room lamp switch connector and ground. Is the inspection result normal? YES >> GO TO 4 NO >> Repair or replace trunk room lamp switch ground circuit. 4. CHECK BCM OUTPUT SIGNAL 1. Insure trunk lid remains closed during this step. 2. Connect BCM connector. 3. Check voltage between BCM connector and ground. Is the inspection result normal? YES >> GO TO 5 NO >> Replace BCM. Refer to BCS-69, "Removal and Installation" 5. CHECK TRUNK ROOM LAMP SWITCH DLK-106, "Component Inspection" . Is the inspection result normal? YES >> GO TO 6 NO >> Replace trunk room lamp switch. 6. CHECK INTERMITTENT INCIDENT GI-45, "Intermittent Incident" >> Inspection End. Component Inspection INFOID:0000000009268792 1. CHECK TRUNK ROOM LAMP SWITCH 1. Turn ignition switch OFF. 2. Disconnect trunk room lamp switch connector. 3. Check trunk room lamp switch. BCM connector Terminal Ground Continuity M100 51 No Trunk room lamp switch connector Terminal Ground Continuity B50 2 Yes Terminals Voltage (V) (Approx.) (+) (–) BCM connector Terminal M100 51 Ground JPMIA0011GB |