Nissan Rogue. Manual - part 805

 

  Index      Nissan     Nissan Rogue (2015 year) - Service and Repair Manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  803  804  805  806   ..

 

 

Nissan Rogue. Manual - part 805

 

 

INTERIOR ROOM LAMP POWER SUPPLY CIRCUIT

INL-47

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

K

M

A

B

INL

N

O

P

YES

>> GO TO 3.

NO

>> Repair or replace harnesses.

3.

CHECK INTERIOR ROOM LAMP RELAY POWER SUPPLY CIRCUIT

1. Check voltage at room lamp relay harness connector.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harnesses.

4.

CHECK INTERIOR ROOM LAMP RELAY POWER SUPPLY OUTPUT

1. Reconnect room lamp relay.

2. Check voltage at room lamp relay harness connector.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace room lamp relay.

5.

CHECK INTERIOR ROOM LAMP RELAY POWER SUPPLY OUTPUT

1. Disconnect he following connectors:

-

Room lamp relay M12

-

Map lamp assembly R6

-

Room lamp R15

-

Personal lamps 2nd row R16 

-

Vanity mirror lamp LH R14

-

Vanity mirror lamp RH R10

-

Luggage room lamp B118

2. Check continuity between room lamp relay connector M12 and interior room lamp connector in question.

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> Repair or replace harnesses.

6.

CHECK INTERIOR ROOM LAMP RELAY POWER SUPPLY OUTPUT SHORT CIRCUIT

Check continuity between room lamp relay and ground.

Room lamp relay

Voltage

(Approx.)

Connector

Terminal

M12

1

Battery voltage

3

Room lamp relay

Voltage

(Approx.)

Connector

Terminal

M12

5

Battery voltage

Room lamp relay

Each interior room lamp

Continuity

Connector

Terminal

Connector

Terminal

M12

5

Map lamp assembly 

R6

1

Yes

Room lamp 

R15

2

Personal lamps 2nd row  

R16

2

Vanity mirror lamp LH 

R14

1

Vanity mirror lamp RH 

R10

1

Luggage room lamp 

B118

1

Room lamp relay

Continuity

Connector

Terminal

M12

5

Ground

No

INL-48

< DTC/CIRCUIT DIAGNOSIS >

INTERIOR ROOM LAMP POWER SUPPLY CIRCUIT

Is the inspection result normal?

YES

>> Check that each interior lamp has no internal short circuit.

NO

>> Repair or replace harnesses.

INTERIOR ROOM LAMP CONTROL CIRCUIT

INL-49

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

K

M

A

B

INL

N

O

P

INTERIOR ROOM LAMP CONTROL CIRCUIT

Description

INFOID:0000000011279213

Controls each interior room lamp (ground side) by PWM signal.

NOTE:

PWM signal control period is approximately 250 Hz (in the gradual brightening/dimming).

Component Function Check

INFOID:0000000011279214

CAUTION:

 Before performing the diagnosis, check that the following is normal:

• Interior room lamp power supply

• Map lamp bulb

• Room lamp bulb

1.

CHECK INTERIOR ROOM LAMP CONTROL FUNCTION

CONSULT ACTIVE TEST

1. Switch the map lamp switch and room lamp switch to DOOR.

2. Turn ignition switch ON.

3. Select “INT LAMP” in “Active Test” of “BCM”.

4. With operating the test items, check that each interior room lamp turns ON/OFF (gradual brightening/dim-

ming).

Does the interior room lamp turns ON/OFF (gradual brightening/dimming)?

YES

>> Interior room lamp control circuit is normal.

NO

>> Refer to 

INL-49, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000011279215

1.

CHECK INTERIOR ROOM LAMP CONTROL OUTPUT

CONSULT ACTIVE TEST

1. Turn ignition switch OFF.

2. Remove all the bulbs of map lamp and room lamp.

3. Turn ignition switch ON.

4. Select “INT LAMP” in “Active Test” of “BCM”.

5.  With operating the test item, check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 2.

Fixed ON>>GO TO 3.

Fixed OFF>>Replace BCM. Refer to 

BCS-75, "Removal and Installation"

 (with Intelligent Key system) or

BCS-135, "Removal and Installation"

 (without Intelligent Key system).

2.

CHECK INTERIOR ROOM LAMP CONTROL OPEN CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect BCM connector, map lamp assembly and room lamp connector.

3. Check continuity between BCM harness connector and map lamp assembly harness connector.

On

: Interior room lamp gradual brightening

Off

: Interior room lamp gradual dimming

BCM

Ground

Test item

Continuity

Connector

Terminal

M20

162

INT LAMP

On

Yes

Off

No

INL-50

< DTC/CIRCUIT DIAGNOSIS >

INTERIOR ROOM LAMP CONTROL CIRCUIT

4. Check continuity between BCM harness connector and room lamp harness connector.

Is the inspection result normal?

YES

>> Replace map lamp assembly or room lamp.

NO

>> Repair or replace harnesses.

3.

CHECK INTERIOR ROOM LAMP CONTROL SHORT CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect BCM connector, map lamp assembly connector and room lamp connector.

3. Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to 

BCS-75, "Removal and Installation"

 (with Intelligent Key system) or 

BCS-

135, "Removal and Installation"

 (without Intelligent Key system).

NO

>> Repair or replace harnesses.

BCM

Map lamp assembly

Continuity

Connector

Terminal

Connector

Terminal

M20

162

R6

3

Yes

BCM

Room lamp

Continuity

Connector

Terminal

Connector

Terminal

M20

162

R15

1

Yes

BCM

Ground

Continuity

Connector

Terminal

M20

162

No

 

 

 

 

 

 

 