CHG-14 < DTC/CIRCUIT DIAGNOSIS > L TERMINAL CIRCUIT (OPEN) L TERMINAL CIRCUIT (OPEN) Description INFOID:0000000009465974 The “L” terminal circuit controls the charge warning lamp. The charge warning lamp turns ON when the igni- tion switch is set to ON or START. When the generator is providing sufficient voltage with the engine running, the charge warning lamp turns OFF. If the charge warning lamp illuminates with the engine running, a malfunc- tion is indicated. Diagnosis Procedure INFOID:0000000009465975 Regarding Wiring Diagram information. Refer to 1. CHECK “L” TERMINAL CONNECTION 1. Turn ignition switch OFF. 2. Check if “L” terminal is clean and tight. Is the inspection result normal? YES >> GO TO 2. NO >> Repair “L” terminal connection. Confirm repair by performing complete Charging system test using EXP-800 NI or GR8-1200 NI (if available). Refer to applicable Instruction Manual for proper testing procedures. 2. CHECK “L” TERMINAL CIRCUIT (OPEN) 1. Disconnect the generator connector. 2. Apply ground to generator harness connector terminal. 3. Check condition of the charge warning lamp with the ignition switch in the ON position. Does it illuminate? YES >> “L” terminal circuit is normal. Refer to CHG-2, "Work Flow (With EXP-800 NI or GR8-1200 NI)" or CHG-5, "Work Flow (Without EXP-800 NI or GR8-1200 NI)" . NO >> GO TO 3. 3. CHECK HARNESS CONTINUITY (OPEN CIRCUIT) 1. Disconnect the battery cable from the negative terminal. 2. Disconnect the combination meter connector. 3. Check continuity between generator harness connector and combination meter harness connector. Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace the harness or connectors. 4. CHECK HARNESS CONTINUITY (OPEN CIRCUIT) Check continuity between combination meter harness connector and fuse block (J/B). Generator Ground Condition Connector Terminal Ignition switch position Charge warning lamp F7 2 ON Illuminate Generator Combination meter Continuity Connector Terminal Connector Terminal F7 2 M24 25 Yes Combination meter Fuse box (J/B) Continuity Connector Terminal Connector Terminal M24 2 M5 12M Yes |