DLK-96 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] DOOR LOCK ACTUATOR Is the inspection result normal? YES >> Replace rear door lock actuator RH. NO >> GO TO 2. 2. CHECK DOOR LOCK ACTUATOR CIRCUIT 1. Disconnect BCM connector and all door lock actuator connectors. 2. Check continuity between BCM harness connector and rear door lock actuator RH harness connector. 3. Check continuity between BCM harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness. 3. CHECK BCM OUTPUT SIGNAL 1. Connect BCM connector. 2. Check voltage between rear door lock actuator RH harness connector and ground. Is the inspection result normal? YES >> Check for internal short of each door lock actuator. NO >> Replace BCM. Refer to BCS-73, "Removal and Installation" (+) (–) Condition Voltage (Approx.) Rear door lock actuator RH Connector Terminal D302 5 Ground Door lock and unlock switch Lock 12 V 6 Unlock BCM Rear door lock actuator RH Continuity Connector Terminal Connector Terminal M85 95 D302 5 Yes B24 105 6 BCM Ground Continuity Connector Terminal M85 95 No B24 105 (+) (–) Condition Voltage (Approx.) BCM Connector Terminal M85 95 Ground Door lock and unlock switch Lock 12 V B24 105 Unlock |