DTC P0340 CMP SENSOR EC-871 [VG33E] C D E F G H I J K L M A EC Specification data are reference values and are measured between each terminal and ground. CAUTION: Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam- : Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.) TER- MINAL NO. WIRE COLOR ITEM CONDITION DATA (DC Voltage) 4 OR/B ECM relay (Self shut- [Engine is running] ● For a few seconds after turning ignition switch 0 - 1.5V [Ignition switch: OFF] ● A few seconds passed after turning ignition BATTERY VOLTAGE 44 PU Camshaft position sen- [Engine is running] ● Idle speed NOTE: 0.3 - 0.5V [Engine is running] ● Engine speed is 2,000 rpm 0.3 - 0.5V 49 LG Camshaft position sen- [Engine is running] ● Warm-up condition ● Idle speed NOTE: Approximately 2.5V [Engine is running] ● Engine speed is 2,000 rpm Approximately 2.5V 67 B/P Power supply for ECM [Ignition switch: ON] BATTERY VOLTAGE 72 B/P [Ignition switch: ON] BATTERY VOLTAGE 117 B/P Current return [Engine is running] ● Idle speed BATTERY VOLTAGE SEF997U SEF998U SEF999U SEF001V |