TRUNK LID OPENER SWITCH

DLK-71

< COMPONENT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

NO

>> Repair or replace harness.

3.

CHECK TRUNK LID OPENER SWITCH GROUND CIRCUIT

Check continuity between trunk lid opener switch harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK TRUNK LID OPENER SWITCH

Refer to 

DLK-71, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace trunk lid opener switch. Refer to 

DLK-243, "Removal and Installation"

.

5.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-35, "Intermittent Incident"

.

>> INSPECTION END

Component Inspection

INFOID:0000000003794873

1.

CHECK TRUNK LID OPENER SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect trunk lid opener switch connector.

3.

Check continuity between trunk lid opener switch terminal.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace trunk lid opener switch. Refer to 

DLK-243, "Removal and Installation"

.

Trunk lid opener switch

Ground

Continuity 

Connector

Terminal

M25

2

Existed

Trunk lid opener switch

Condition

Continuity 

Terminal

1

2

ON (press and hold)

Existed

OFF (release)

Not existed

DLK-72

< COMPONENT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

DOOR REQUEST SWITCH

DOOR REQUEST SWITCH

Description

INFOID:0000000003794874

Transmits lock/unlock operation to BCM.

Component Function Check

INFOID:0000000003794875

1.

CHECK FUNCTION

Check door request switch (“REQ SW-DR” or “REQ SW-AS”) in Data Monitor mode.

Is the inspection result normal?

YES

>> Door request switch is OK.

NO

>> Refer to 

DLK-72, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000003794876

1.

CHECK BCM OUTPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect malfunctioning front outside handle (request switch) connector.

3.

Check signal between malfunctioning front outside handle (request switch) harness connector and ground
with oscilloscope.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK DOOR REQUEST SWITCH CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between BCM harness connector and malfunctioning front outside handle (request
switch) harness connector.

3.

Check continuity between BCM harness connector and ground.

Monitor item

Condition

DR REQ SW
AS REQ SW

Door request switch is pressed: ON

Door request switch is released: OFF

(+)

(–)

Signal

(Reference value)

Front outside handle (request switch)

Connector

Terminal

LH

D11

1

Ground

RH

D50

JMKIA0059GB

BCM

Front outside handle (request switch)

Continuity 

Connector

Terminal

Connector

Terminal

M122

101

LH

D11

1

Existed

100

RH

D50

DOOR REQUEST SWITCH

DLK-73

< COMPONENT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

Is the inspection result normal?

YES

>> Replace BCM. Refer to 

BCS-78, "Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK DOOR REQUEST SWITCH GROUND CIRCUIT

Check continuity between malfunctioning front outside handle (request switch) harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 4.

NO

>> Repair or replace harness.

4.

CHECK DOOR REQUEST SWITCH

Refer to 

DLK-73, "Component Inspection"

.

Is the inspection result normal?

YES

>> GO TO 5.

NO

>> Replace malfunctioning front outside handle. Refer to 

DLK-224, "OUTSIDE HANDLE : Removal

and Installation"

.

5.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-35, "Intermittent Incident"

.

>> INSPECTION END 

Component Inspection

INFOID:0000000003794877

1.

CHECK DOOR REQUEST SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect front outside handle (request switch) connector.

3.

Check front outside handle (request switch).

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace front outside handle. Refer to 

DLK-224, "OUTSIDE HANDLE : Removal and Installation"

.

BCM

Ground

Continuity 

Connector

Terminal

M122

101

Not existed

100

Front outside handle (request switch)

Ground

Continuity 

Connector

Terminal

LH

D11

2

Existed

RH

D50

Front outside handle (request switch)

Door request switch condition

Continuity

Terminal

1

2

Pressed

Existed

Released

Not existed

DLK-74

< COMPONENT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

TRUNK LID OPENER REQUEST SWITCH

TRUNK LID OPENER REQUEST SWITCH

Description

INFOID:0000000003794878

Performs trunk lid open request when it is pressed.

Component Function Check

INFOID:0000000003794879

1.

CHECK FUNCTION

Check trunk lid opener request switch (“REQ SW -BD/TR ”) in Data Monitor mode.

Is the inspection result normal?

YES

>> Trunk lid opener request switch is OK.

NO

>> Refer to 

DLK-74, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000003794880

1.

CHECK TRUNK LID OPENER SWITCH OUTPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect trunk lid opener request switch connector.

3.

Check signal between trunk lid opener request switch harness connector and ground with oscilloscope.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK TRUNK LID OPENER REQUEST SWITCH CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between BCM harness connector and trunk lid opener request switch harness connec-
tor.

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

Monitor item

Condition

 REQ SW -BD/TR 

Trunk lid opener request switch is pressed: ON

Trunk lid opener request switch is released: OFF

(+)

(–)

Signal

(Reference value)

Trunk lid opener request switch

Connector

Terminal

T6

1

Ground

JPMIA0016GB

BCM

Trunk lid opener request switch

Continuity 

Connector

Terminal

Connector

Terminal

M121

61

T6

1

Existed

BCM

Ground

Continuity 

Connector

Terminal

M121

61

Not existed

 

 

 

 

 

 

 

Content   ..  320  321  322  323   ..