MWI-100 < SYMPTOM DIAGNOSIS > THE AMBIENT TEMPERATURE DISPLAY IS INCORRECT THE AMBIENT TEMPERATURE DISPLAY IS INCORRECT Description INFOID:0000000009721324 • The displayed ambient air temperature is higher than the actual temperature. Diagnosis Procedure INFOID:0000000009721325 NOTE: MWI-101, "INFORMATION DISPLAY : Description" 1. CHECK AMBIENT SENSOR SIGNAL CIRCUIT Check the ambient sensor signal circuit. Refer to (without 7 inch display) or HAC-173, "Diagnosis Procedure" (with 7 inch display). Is the inspection result normal? YES >> GO TO 2. NO >> Repair harness or connector. 2. CHECK A/C AUTO AMP. CONNECTION RECOGNITION SIGNAL CIRCUIT Check the A/C auto amp. connection recognition signal circuit. Refer to Is the inspection result normal? YES >> GO TO 3. NO >> Repair harness or connector. 3. CHECK AMBIENT SENSOR Perform a unit check for the ambient sensor. Refer to HAC-48, "Component Inspection" (without 7 inch dis- play) or HAC-174, "Component Inspection" (with 7 inch display). Is the inspection result normal? YES >> Replace combination meter. NO >> Replace ambient sensor. Refer to VTL-26, "Removal and Installation" (without 7 inch display) or VTL-90, "Removal and Installation" (with 7 inch display). |