FEEDING

282

D

AILY

Base - May 2004

1 - START OF DELIVERY

Pre-lift (from B.D.C.)

mm:

0

± 0.02

2 - ADVANCE CHANGER TRAVEL

Speed

rpm:

1250

Overcharging pressure

hPa:

Adjustment values

mm:

2.8

± 0.1

3 - TRANSFER PUMP PRESSURE

Speed

rpm:

1250

Overcharging pressure

hPa:

Adjustment values

bar:

6.2

± 0.2

4 - DELIVERY AT FULL LOAD WITH OVERCHARGING

Speed

rpm:

Overcharging pressure

hPa:

Delivery per 1000 shots

cm

3

:

Max difference

cm

3

:

Timing:
-

Injection pump static advance (Output reference ”A”) 1.0

° ± 0.5°

degrees before | | after |X| T.D.C. with I.P. pumping in phase of delivery at 1 mm from B.D.C.

-

Or with piston at T.D.C. and injection pump pumping in phase of delivery at 0.94

± 0.05 mm from B.D.C.

-

Engine idling speed without load: 800

± 25 rpm

I V E C O

E N G I N E E R I N G

Edit. 1

I N J E C T I O N R O T A R Y P U M P T E S T V A L U E S

Injection pump:

VE4/9F1900R808-1

Speed governor: MIN/MAX

IVECO PART N.: 500329480
BOSCH PART N.:0460 494 470

Engine :

8140.63.4000

For:

IVECO

TEST BENCH WITH STATIC AND DYNAMIC CHARACTERISTICS

CONFORMING TO STANDARDS ISO 4008/1 -/2

-

Rotation direction:

Right

X

Left

-

Pipes:

∅ 6 x ∅ 2 x 450 mm

-

Injectors: 1688 901 022

-

Calibrated hole pad: -

-

Injector setting : 130 + 3 bar

-

Backflow chock:

∅ 0.55 mm

-

Supply pressure:

0.35

± 0.05 bar

-

Burette evacuation time:

KMM

-

Test fluid conforming to standard:

ISO 4113

-

Temperature

Influx
Defluxion

X

-

Thermometer

: 45

± 1 °C

-

Electronic

:

± 4 °C

”INJECTION PUMP ADJUSTMENT VALUES”

”THE NUMBERS GIVEN IN BRACKETS SHOULD

BE USED ONLY AS CONTROL VALUES”

5 - DELIVERY AT FULL LOAD WITHOUT

OVERCHARGING

Speed

rpm:

1250

Delivery per 1000 shots

cm

3

:

53.0

± 0.5

Max difference

cm

3

:

3.0 (3.0)

6 - IDLE SPEED ADJUSTMENT

Speed

rpm:

375

Delivery per 1000 shots

cm

3

:

13.0

± 2.0

Max difference

cm

3

:

3.0 (3.50)

7 - ADJUSTING THE RESIDUAL DELIVERY

Speed

rpm:

Delivery per 1000 shots

cm

3

:

8 - MAXIMUM SPEED ADJUSTMENT

Speed

rpm:

2050

Overcharging pressure

hPa:

Delivery per 1000 shots

cm

3

:

43.0

± 1.0

Date: 26-06-1998

Sheet 1/4

No. 500338906

FEEDING

283

D

AILY

FEEDING

INJECTION PUMP TEST VALUES

I V E C O

E N G I N E E R I N G

No. 500338906

Edit. 1

I N J E C T I O N R O T A R Y P U M P T E S T V A L U E S

9 - START

Speed

rpm:

100

Delivery per 1000 shots

cm

3

:

80.0

± 15

Minimum delivery

cm

3

:

65.0

10 - ”LFB” SETTING

Speed

rpm:

1250

Overcharging pressure

hPa:

-

1. Delivery difference

per 1000 shots

cm

3

:

< 12

± 1.0

2. Transfer pump pressure

difference

bar:

0.2

± 0.1

11 - INJECTION ADVANCE RUN

Overcharging pressure

hPa:

-

.1 Speed

rpm:

1250

Advance travel

mm:

2.8

± 0.1

mm:

(

± 0.5)

.2 Speed

rpm:

1700

Advance travel

mm:

5.5

± 0.4

mm:

(

± 0.6)

.3 Speed

rpm:

-

Advance travel

mm:

-

mm:

-

.4 Speed

rpm:

-

Advance travel

mm:

-

mm:

-

12 - TRANSFER PRESSURE RUN

Overcharging pressure

hPa:

-

.1 Speed

rpm:

1250

Transfer pump pressure

bar:

6.2

± 0.2

.2 Speed

rpm:

1900

Transfer pump pressure

bar:

8.5

± 0.5

.3 Speed

rpm:

-

Transfer pump pressure

bar:

-

.4 Speed

rpm:

-

Transfer pump pressure

bar:

-

13 - BACKFLOW VOLUME ON VALVE

.1 Speed

rpm:

600

Overcharging pressure

hPa:

-

Backflow volume

c.c./10s:

41.4

÷ 74.52

c.c./10s:

(41.4

÷ 74.52)

.2 Speed

rpm:

1900

Overcharging pressure

hPa:

Backflow volume

c.c./10s:

60.7

÷ 104.8

c.c./10s:

(60.7

÷ 104.8)

14 - DELIVERY RUN AND ADJUSTMENT

.1 Speed

rpm:

(*)

Overcharging pressure

hPa:

-

Delivery per 1000 shots

cm

3

:

-

cm

3

:

-

.2 Speed

rpm:

2380

Overcharging pressure

hPa:

Delivery per 1000 shots

cm

3

:

1.5

± 1.5

cm

3

:

(

± 1.5)

.3 Speed

rpm:

2150

Overcharging pressure

hPa:

Delivery per 1000 shots

cm

3

:

23.0

± 5.0

cm

3

:

(

± 6.0)

.4 Speed

rpm:

2050

Overcharging pressure

hPa:

Delivery per 1000 shots

cm

3

:

43.0

± 1.0

cm

3

:

(

± 6.0)

.5 Speed

rpm:

1900

Overcharging pressure

hPa:

Delivery per 1000 shots

cm

3

:

50.0

± 2.0

cm

3

:

(

± 2.5)

.6 Speed

rpm:

1250

Overcharging pressure

hPa:

Delivery per 1000 shots

cm

3

:

53.0

± 0.5

cm

3

:

(

± 2.0)

.7 Speed

rpm:

600

Overcharging pressure

hPa

Delivery per 1000 shots

cm

3

:

52.0

± 2.5

cm

3

:

(

± 3.0)

.8 Speed

rpm:

-

Overcharging pressure

hPa:

-

Delivery per 1000 shots

cm

3

:

-

cm

3

:

-

.9 Speed

rpm:

-

Overcharging pressure

hPa:

-

Delivery per 1000 shots

cm

3

:

-

cm

3

:

-

.10 Speed

rpm:

-

Overcharging pressure

hPa:

-

Delivery per 1000 shots

cm

3

:

-

cm

3

:

-

Date:

26-06-1998

Sheet 2/4

FEEDING

284

D

AILY

Base - May 2004

I V E C O

E N G I N E E R I N G

No. 500338906

Edit. 1

I N J E C T I O N R O T A R Y P U M P T E S T V A L U E S

15 - DELIVERY NULL (STOP)

.1 Mechanical:

Speed

rpm:

460

Delivery per 1000 shots

cm

3

:

1.5

± 1.5

Voltage

volt:

0

.2 Electrical:

Speed

rpm:

375

Delivery per 1000 shots

cm

3

:

1.5

± 1.5

Voltage

volt:

0

16 - DELIVERY AT IDLING SPEED

.1 Speed

rpm:

375

Delivery per 1000 shots

cm

3

:

13.0

± 1.0

(

± 5.0)

.2 Speed

rpm:

300

Delivery per 1000 shots

cm

3

:

28.0

± 6.0

(

± 6.0)

.3 Speed

rpm:

460

Delivery per 1000 shots

cm

3

:

1.5

± 1.5

.4 Speed

rpm:

Delivery per 1000 shots

cm

3

:

Residual delivery check

.5 Speed

rpm

Delivery per 1000 shots

cm

3

17 - ”LFB” CHECK

Speed

rpm:

1250

Overcharging pressure

hPa:

.1 Delivery difference

per 1000 shots

cm

3

:

17.0

± 3.0

Advance travel diff.

mm:

1.0

± 0.1

.2 Delivery per 1000 shots

cm

3

:

5.0

± 1.0

Advance travel diff.

mm:

18 - AUTOMATIC START EXTRA DELIVERY

.1 Speed

rpm:

100

Delivery per 1000 shots

cm

3

:

80.0

± 15

cm

3

:

65 min.

.2 Speed

rpm:

400

Delivery per 1000 shots

cm

3

:

65.0

± 8

cm

3

:

73 max.

.3 Speed

rpm:

Delivery per 1000 shots

cm

3

:

cm

3

:

19 - POTENTIOMETER CALIBRATION AND CHECKING

Supply

volt:

5.0

Setting
Speed

rpm:

1000

Delivery per 1000 shots

cm

3

33.8

± 0.5

Potentiometer output voltage

volt:

3.25

± 0..1

Checking:
Speed

rpm:

Delivery per 1000 shots

cm

3

:

Potentiometer output voltage

volt:

20 - EGR MICROSWITCH CALIBRATION

Speed

rpm:

Overcharging pressure

hPa:

Delivery per 1000 shots

cm

3

:

21 - GLOW PLUG MICROSWITCH ADJUSTMENT

Contact closed at:
of injection pump
control lever travel

22 - CUT-OUT ELECTROMAGNET

Operating minimum voltage

volt:

10

Rated voltage

volt:

12

23 - ASSEMBLING AND ADJUSTING DIMENSIONS

Denomination:
K

mm:

3.7

KF

mm:

MS

mm:

1.6

SVS max.

mm:

MSI

mm:

Ya

mm:

38.9

± 1.0

Yb

mm:

44.5

± 3.0

TLA-E

mm:

Devices
HBA STROKE

mm:

LDA STROKE

mm:

KSB LEVER

:

KSB SPEED R.P.M

:

KSB TRANSFER

bar:

KSB SPEED R.P.M

:

KSB ADVANCE

mm:

2.8

KSB ADVANCE A.P. DEGREES

:

3.5

KSB VOLT EL. VALVE

:

Date:

26-06-1998

Sheet 3/4

FEEDING

285

D

AILY

 

 

 

 

 

 

 

Content   ..  73  74  75  76   ..