Content .. 1208 1209 1210 1211 ..
INL-40 < DTC/CIRCUIT DIAGNOSIS > PERSONAL LAMP CIRCUIT PERSONAL LAMP CIRCUIT Description INFOID:0000000005245574 Controls the lamp (ground side) by PWM signal (duty) when map Component Function Check INFOID:0000000005245575 CAUTION: Before performing the diagnosis, check that the following items are normal. 1. CHECK PERSONAL LAMP CONTROL FUNCTION CONSULT-III ACTIVE TEST 1. Turn ignition switch ON. 2. Select “PERSONAL LAMP-RR” or “PERSONAL LAMP-RL” of TOTAL ILLUM C/U active test item. 3. While operating the test items, check personal lamps operation. Are the personal lamps turned ON/OFF? YES >> Personal lamp circuit is normal. NO >> Refer to . Diagnosis Procedure INFOID:0000000005245576 1. CHECK PERSONAL LAMP CONTROL OUTPUT CONSULT-III ACTIVE TEST 1. Turn ignition switch ON. 2. Select “PERSONAL LAMP-RR” or “PERSONAL LAMP-RR” of TOTAL ILLUM C/U active test item. 3. While operating the test items, check voltage between total illumination control unit harness connector Personal lamp RH JPLIA1210GB Test item Operation PERSONAL On Personal lamp ON Off OFF PERSONAL On Personal lamp ON Off OFF Total illumination control unit Ground Test item Voltage (Approx.) Connector Terminal PERSONAL LAMP-RR M129 14 On 0 V Off 12 V |