5
2. Measure the voltage from the
signal B circuit of the TR
switch connector to ground.
3. Measure the voltage from the
signal C circuit of the TR
switch connector to ground.
4. Measure the voltage from the
signal P circuit of the TR
switch connector to ground.
Does the voltage measure within the
specified value at all four circuits?
10-12 V
Go to Step 6
Go to Step
11
6
Connect a fused jumper wire from
the TR switch connector, signal
circuit A, to ground while
monitoring the scan tool TR Sw.
A/B/C/P parameter.
When signal circuit A is grounded,
do any other signal circuits indicate
LOW?
-
Go to Step 12 Go to Step 7
7
Connect a fused jumper wire from
the TR switch connector, signal
circuit B, to ground while
monitoring the scan tool TR Sw.
A/B/C/P parameter.
When signal circuit B is grounded,
do any other signal circuits indicate
LOW?
-
Go to Step 12 Go to Step 8
8
Connect a fused jumper wire from
the TR switch connector, signal
circuit C, to ground while
monitoring the scan tool TR Sw.
A/B/C/P parameter.
When signal circuit C is grounded,
do any other signal circuits indicate
LOW?
-
Go to Step 12 Go to Step 9
Connect a fused jumper wire from
the TR switch connector, signal
circuit P, to ground while
2007 Hummer H3
2007 TRANSMISSION Automatic Transmission - 4L60-E/4L65-E/4L70-E - H3