Hummer H3. Manual - part 1292

 

  Index      Hummer     Hummer H3 - service repair manual 2006-2009 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  1290  1291  1292  1293   ..

 

 

Hummer H3. Manual - part 1292

 

 

5 

6. Record the ambient 

temperature at the vehicle.  

7. Record readings of the low 

and high side STATIC 
pressures.  

8. Compare the low and the high 

side pressure values with the 
allowable limits for the 
recorded ambient air 
temperature.  

Are the low and the high side 
pressure values within the 
allowable limits for the recorded 
ambient air temperature. Are the 
pressure values within 103 kPa (15 
psi) of each other?



Above 

24°C 

(75°F) 

483 kPa 

(70 psi)  



Above 

33°C 

(90°F) 

690 kPa 

(100 psi) 

Go to Step 6 

Go to Leak 
Testing
 

6

1. Disconnect the A/C 

compressor relay.  

2. Probe the battery positive 

voltage circuit of the A/C 
compressor clutch relay with 
a test lamp connected to a 
good ground.  

Does the test lamp illuminate?

-

Go to Step 7 

Go to Step 

18 

7 

Connect a 10-amp fused jumper 
between the battery positive 
voltage circuit and the A/C 
compressor clutch supply voltage 
circuit of the A/C compressor 
clutch relay. 
Does the A/C compressor clutch 
engage?

-

Go to Step 19 

Go to Step 

13 

IMPORTANT:

Access the evaporator temperature 
sensor gray control circuits and 
module with 2-way connector to BCM 
and HVAC control module behind the 

 

2007 Hummer H3 

2007 HVAC HVAC - Manual - H3

  

8 

1. Disconnect the evaporator 

temperature sensor at the 2-
wire connector running from 
the evaporator temperature 
control circuits to the HVAC 
control module and BCM 
behind the glove box.  

2. Connect a test light between 

the A/C request circuit of the 
HVAC control module and 
the BCM at the 2-wire 
connector of the evaporator 
temperature sensor.  

Does the A/C compressor engage?

glove box.

-

Go to Step 9 

Go to Step 

11 

9 

1. With a 3-amp fused jumper 

attached between the BCM 
and the HVAC control 
module A/C request circuits 
at the 2-wire evaporator 
temperature sensor behind the 
glove box.  

2. Check the resistance of the 2 

gray evaporator temperature 
sensor circuits at the 
evaporator temperature 
sensor behind the glove box.  

3. Start the engine.  

Does the resistance value stay 
within the specified value range 

IMPORTANT:

Access the evaporator temperature 
sensor gray control circuits and 
module with 2-way connector to BCM 
and HVAC control module behind the 
glove box.

Temperature 

Minimum 

14.9°C 

(58.82°F) - 

Resistance 

Minimum 

15651 ohms 

Temperature 

Maximum 

30.1°C 

(86.18°F) - 

Resistance 

Maximum 

8190 ohms

Go to Step 

 

2007 Hummer H3 

2007 HVAC HVAC - Manual - H3

  

even after compressor engagement?

Go to Step 25 

10 

10 

1. With a 3-amp fused jumper 

attached between the BCM 
and the HVAC control 
module A/C request circuits 
at the 2-wire evaporator 
temperature sensor behind the 
glove box.  

2. Cut the 2 gray evaporator 

temperature sensor circuits no 
less than 2 inches from the 
evaporator temperature 
sensor module behind the 
glove box.  

3. Start the engine.  

4. Check the resistance of the 2 

gray wires at the evaporator 
temperature sensor coming 
out of the evaporator core at 
the HVAC module.  

Does the resistance value move 
from the specified value range 
when the compressor is engaged?

IMPORTANT:

Access the evaporator temperature 
sensor gray control circuits and 
module with 2-way connector to BCM 
and HVAC control module behind the 
glove box.

Temperature 

Minimum 

14.9°C 

(58.82°F) - 

Resistance 

Minimum 

15651 ohms 

Temperature 

Maximum 

30.1°C 

(86.18°F) - 

Resistance 

Maximum 

8190 ohms

Go to Step 25 

Go to Step 

26 

11

1. Disconnect the evaporator 

temperature sensor at the 2-
wire pinout running to the 
HVAC control module 

IMPORTANT:

Access the evaporator temperature 
sensor control circuits and module 
through the glove box.

12 V

 

2007 Hummer H3 

2007 HVAC HVAC - Manual - H3

  

behind the radio.  

2. Probe the A/C request signal 

circuit of the HVAC control 
module with a DMM 
connected to a good ground.  

Does the DMM indicate at least 
the specified value?

Go to Step 12 

Go to Step 

15 

12

1. Connect a 3-amp fused 

jumper between the A/C 
request signal circuit of the 
HVAC control module and 
the A/C request signal circuit 
of the BCM.  

2. Observe the A/C Request 

Signal parameter.  

Does the scan tool indicate the A/C 
Request Signal parameter is Yes?

-

Go to Step 20 

Go to Step 

17 

13

Test the ground circuit of the A/C 
compressor clutch for a high 
resistance or for an open. Refer to 
Circuit Testing and Wiring 
Repairs
 . 
Did you find and correct the 
condition?

-

Go to Step 30 

Go to Step 

14 

14

Test the supply voltage circuit of 
the A/C compressor clutch for a 
high resistance or for an open. 
Refer to Circuit Testing and 
Wiring Repairs . 
Did you find and correct the 
condition?

-

Go to Step 30 

Go to Step 

23 

15

Test the A/C request signal circuit 
of the HVAC control module for a 
short to ground, a high resistance 
and for an open. Refer to Circuit 
Testing
 and Wiring Repairs . 
Did you find and correct the 

-

Go to Step 

 

2007 Hummer H3 

2007 HVAC HVAC - Manual - H3

  

 

 

 

 

 

 

 

Content   ..  1290  1291  1292  1293   ..