A/C Performance Table 

Does all the data recorded fall 
within the specified ranges of the 
A/C performance table?

Go to Step 8  Go to Step 4 

4

Do the high and low side pressures 
fall within the specified ranges, but 
the panel outlet temperatures do 
not?

-

Go to Air 
Conditioning 
(A/C) 
Diagnostics - 
Pressure Zone 
A

Go to Step 5 

5

Is the low side pressure greater 
than the specified range, but the 
high side pressure within or less 
than the specified range?

-

Go to Air 
Conditioning 
(A/C) 
Diagnostics - 
Pressure Zone 
B

Go to Step 6 

6

Are the low and high side pressures 
both greater than the specified 
ranges?

-

Go to Air 
Conditioning 
(A/C) 
Diagnostics - 
Pressure Zone 
C

Go to Step 7 

7

Is the high side pressure greater 
than the specified range, but the 
low side pressure is within or less 
than the specified range?

-

Go to Air 
Conditioning 
(A/C) 
Diagnostics - 
Pressure Zone 
D

Go to Step 8 

8

Operate the system in order to 
verify the test results. 
Did you find the same results?

-

System OK

Go to 
Symptoms - 
HVAC 
Systems - 
Manual
 

Ambient 

Temperature

Relative 

Humidity

Low Side 

Service Port 

Pressure

High Side 

Service Port 

Pressure

Maximum Left 

Center 

Discharge Air 

Temperature

13-18°C (55-65°

151-192 kPa 

716-1198 kPa 

 

2007 Hummer H3 

2007 HVAC Heating, Ventilation and Air Conditioning - H3

  

F)

0-100%

(22-28 psi)

(104-174 psi)

7°C (43°F)

19-24°C (66-75°

F)

Below 40%

151-248 kPa 

(22-36 psi)

888-1391 kPa 

(129-202 psi)

8°C (46°F)

Above 40%

158-234 kPa 

(23-34 psi)

992-1481 kPa 

(144-215 psi)

8°C (46°F)

25-29°C (76-85°

F)

Below 35%

199-275 kPa 

(29-40 psi)

1247-1646 kPa 

(181-239 psi)

12°C (52°F)

35-50%

199-268 kPa 

(29-39 psi)

1302-1667 kPa 

(189-242 psi)

12°C (52°F)

Above 50%

192-254 kPa 

(28-37 psi)

1329-1708 kPa 

(193-248 psi)

12°C (52°F)

30-35°C (86-95°

F)

Below 30%

206-316 kPa 

(30-46 psi)

1543-1970 kPa 

(224-286 psi)

15°C (59°F)

30-50%

220-303 kPa 

(32-44 psi)

1557-1977 kPa 

(226-287 psi)

15°C (59°F)

Above 50%

220-289 kPa 

(32-42 psi)

1591-1991 kPa 

(231-289 psi)

16°C (60°F)

36-41°C (96-105°

F)

Below 20%

275-372 kPa 

(40-54 psi)

1887-2321 kPa 

(274-337 psi)

20°C (68°F)

20-40%

282-351 kPa 

(41-51 psi)

1887-2301 kPa 

(274-334 psi)

20°C (68°F)

Above 40%

254-330 kPa 

(37-48 psi)

1901-2280 kPa 

(276-331 psi)

21°C (69°F)

42-46°C (106-

115°F)

Below 20%

310-406 kPa 

(45-59 psi)

2239-2597 kPa 

(325-377 psi)

23°C (73°F)

Above 20%

330-431 kPa 

(48-60 psi)

2239-2569 kPa 

(325-373 psi)

24°C (75°F)

47-49°C (116-

120°F)

Below 30%

372-468 kPa 

(54-68 psi)

2521-2859 kPa 

(366-415 psi)

27°C (80°F)

 

2007 Hummer H3 

2007 HVAC Heating, Ventilation and Air Conditioning - H3

  

Fig. 1: A/C System Pressure Zone Classification 
Courtesy of GENERAL MOTORS CORP. 

AIR CONDITIONING (A/C) DIAGNOSTICS - PRESSURE ZONE A 

Air Conditioning (A/C) Diagnostics - Pressure Zone A 

Step

Action

Value

Yes

No

DEFINITION: The high and low side pressures may be normal or slightly less than normal. 



Air Delivery Concern  



Slight Refrigerant Under Charge  



Refrigerant Contamination  

1

Were you sent here from the A/C 
System Performance Test?

-

Go to Step 2 

Go to Air 
Conditioning 
(A/C) System 
Performance 
Test

 

2007 Hummer H3 

2007 HVAC Heating, Ventilation and Air Conditioning - H3

  

2

Refer to the instrument panel outlet 
air temperatures recorded during 
the A/C system performance test. 
Does the discharge air temperature 
between the right and left center 
instrument panel outlets vary by 
more than 1-2°C (2-3°F)?

-

Go to Step 7 

Go to Step 3 

3

Did the customer mention that the 
A/C system output temperatures 
are good at first, but then turn 
warm during extended drives?

-

Go to Step 4 

Go to Step 5 

4

Increase engine speed to 2,000 
RPM. 
During extended operation of the 
A/C system, does the low side 
pressure decrease, possibly 
accompanied by heavy frost on the 
liquid line between the expansion 
device and the evaporator?

-

Go to Air 
Conditioning 
(A/C) 
Diagnostics - 
Pressure Zone 
D

Go to Step 5 

5

1. Refer to the pressures 

recorded during the A/C 
system performance test.  

2. Inspect for the following 

conditions: 



The high side pressure is 
slightly greater than the 
specified pressure 
ranges but still within 
Zone A on the A/C 
Pressure-Zone 
Classification Chart in 
the A/C System 
Performance Test. Refer 

CAUTION:

Refer to Moving Parts 
and Hot Surfaces 
Caution .

-

 

2007 Hummer H3 

2007 HVAC Heating, Ventilation and Air Conditioning - H3

  

 

 

 

 

 

 

 

Content   ..  1251  1252  1253  1254   ..