CHARGE INDICATOR INOPERATIVE 

Charge Indicator Inoperative 

3

2. With a scan tool, observe 

the Battery Voltage 
parameter in the instrument 
panel cluster (IPC) data list. 

Does the voltage measure within 
the normal operating range?

12.5-15.5 V

Go to Step 4 

Go to 
Charging 
System Test

4

Replace the IPC. Refer to 
Control Module References 
for replacement, setup and 
programming. 
Did you complete the 
replacement?

-

Go to Step 5 

-

5

Operate the system in order to 
verify the repair. 
Did you correct the condition?

-

System OK

Go to Step 2 

Step

Action

Yes

No

1

Did you perform the Diagnostic System 
Check - Vehicle?

Go to Step 2 

Go to 
Diagnostic 
System Check 
- Vehicle
 

2

Turn ON the ignition, with the engine OFF 
observe the charge indicator on the instrument 
panel cluster (IPC). 
Is the charge indicator illuminated?

Go to Testing 
for 
Intermittent 
Conditions 
and Poor 
Connections
 

Go to Step 3 

3

Replace the IPC. Refer to Control Module 
References
 for replacement, setup and 
programming. 
Did you complete the replacement?

Go to Step 4 

-

4

Operate the system in order to verify the 
repair. 
Did you correct the condition?

System OK

Go to Step 2 

 

2007 Hummer H3 

2007 ENGINE Engine Electrical - H3

  

GENERATOR NOISE DIAGNOSIS 

Diagnostic Aids 

Noise from a generator may be due to electrical or mechanical noise. Electrical noise, magnetic 
whine, usually varies with the electrical load placed on the generator and is a normal operating 
characteristic of all generators. When diagnosing a noisy generator, it is important to remember 
that loose or misaligned components around the generator may transmit the noise into the 
passenger compartment and that replacing the generator may not solve the problem. 

Generator Noise Diagnosis 

Step

Action

Yes

No

1

Test the generator for proper operation 
using the Generator Tester. Refer to 
Charging System Test
Is the generator operating properly?

Go to Step 2 

Go to Step 11 

2

1. Start the engine. Verify that the noise 

can be heard.  

2. Turn OFF the engine.  

3. Disconnect the 4-way connector from 

the generator.  

4. Start the engine.  

5. Listen for the noise.  

Has the noise stopped?

Go to Step 11 

Go to Step 3 

3

1. Turn OFF the engine.  

2. Remove the drive belt. Refer to 

Drive Belt Replacement (Without 
A/C)
 or Drive Belt Replacement 
(With A/C)
 .  

3. Spin the generator pulley by hand.  

Does the generator shaft spin smoothly and 
without any roughness or grinding noise?

Go to Step 4 

Go to Step 11 

4

Inspect the generator for a loose pulley 
and/or pulley nut. 
Is the generator pulley or pulley nut loose?

Go to Step 11 

Go to Step 5 

1. Loosen all of the generator mounting 

 

2007 Hummer H3 

2007 ENGINE Engine Electrical - H3

  

5

bolts.  

2. Tighten the generator mounting bolts 

to specifications and in the proper 
sequence, if necessary. Refer to 
Generator Replacement.  

3. Install the drive belt. Refer to Drive 

Belt Replacement (Without A/C) 
or Drive Belt Replacement (With 
A/C)
 .  

4. Start the engine.  

Has the noise decreased or stopped?

System OK

Go to Step 6 

6

Inspect the generator for the following 
conditions: 



Strained or stretched electrical 
connections  



Hoses or other vehicle equipment 
resting on the generator, which may 
cause the noise to be transmitted into 
the passenger compartment  

 
Are any electrical connections pulling on 
the generator or are any hoses, etc. resting 
on the generator?

Go to Step 7 

Go to Step 8 

7

1. Reroute the electrical connections to 

relieve the tension.  

2. Reroute the hoses, etc. away from the 

generator.  

3. Start the engine.  

Has the noise decreased or stopped?

System OK

Go to Step 8 

8

Inspect the drive belt for proper tension. 
Refer to Drive Belt Tensioner 
Diagnosis
 . 
Is the drive belt loose?

Go to Step 9 

Go to Step 10 

1. Replace the drive belt tensioner. 

 

2007 Hummer H3 

2007 ENGINE Engine Electrical - H3

  

STARTER SOLENOID DOES NOT CLICK 

Starter Solenoid Does Not Click 

9

Refer to Drive Belt Tensioner 
Replacement
 .  

2. Start the engine.  

Has the noise decreased or stopped?

System OK

Go to Step 11 

10

Compare the vehicle with a known good 
vehicle. 
Do both vehicles make the same noise?

System OK

Go to Step 11 

11

Replace the generator. Refer to 
Generator Replacement.Has the noise 
decreased or stopped?

IMPORTANT:

If no definite generator problems were found, 
be sure that all other possible sources of 
objectionable noise are eliminated before 
replacing the generator. Replacing the 
generator may not change the noise level if 
the noise is a normal characteristic of the 
generator or the generator mounting.

Go to Step 12 

-

12

Operate the system in order to verify the 
repair. 
Did you correct the condition?

System OK

Go to Step 2 

Step

Action

Yes

No

Schematic Reference: Starting and Charging Schematics

1

Did you perform the Diagnostic System 
Check - Vehicle?

Go to Step 2 

Go to 
Diagnostic 
System Check - 
Vehicle
 

2

Turn the ignition switch to the START 
position. 
Does the engine crank?

Go to Testing 
for Intermittent 
Conditions and 
Poor 
Connections
 

Go to Step 3 

Is the security indicator flashing?

Go to 
Diagnostic 

 

2007 Hummer H3 

2007 ENGINE Engine Electrical - H3

  

 

 

 

 

 

 

 