10.2.4.8 DTC B1211 

Fault diagnosis code Descriptions 

B1211 

The indoor dome lamp is in short circuit until the battery is broken down. 

Circuit diagram: 

NL11-3250b

1 RF12

2 RF12

ACC

15A

IF06

3 RF12

IP49

3

BCM

前顶灯

INTERNAL
-LAMP

 

Diagnostic Steps: 

Inspect whether there is any DTC Code other than B1211. 

(a)  Inspect whether there is any DTC Code other than B1211. 

 

 

 

Measure the voltage of the in-vehicle roof lamp. 

Yes 

Go to 

DTC list in 10.2.4.2

 and repair according to 

trouble codes. 

No 

Front 

ceiling 

lamp 

1915

 
 

(a)  Turn the ignition switch to ON position. 

(b) Open 

indoor 

lamp 

(c)  Measure voltage of dome lamp wire harness 

connector RF12 terminal 3. 

Standard Voltage: 11-14 V 

NL11-3216b

9

8

7

4

3

2

6

5

1

1

2

6

3

4

5

CA18右前组合灯线束连接器

SO24右后组合灯线束连接器

 

 

 

 

Inspect the bulb. 

(a)  Inspect whether dome lamp bulb is burned out. 

Confirm whether the indoor dome lamp bulb is blown out. 

 

 

 

 

Inspect the communication between the fuse and the front 
ceiling lamp. 

No 

Go to step 4 

Yes 

Yes 

Replace the bulb . 

No 

CA18Right front combination lamp harness 

connector

 

SO24Right rearcombination lamp harness connector

1916

 
 

(a)  Turn the ignition switch to OFF position. 

(b)  Disconnect front ceiling harness connector 

RF12. 

(c)  Measure resistance between fuse IF06 and 

front top lamp wire harness connector RF12 
terminal 3. 

Standard Resistance: Less than 1 Ω 

Confirm if the resistance conforms to standard 
value. 

 

NL11-3215b

9

8

7

4

3

2

6

5

1

1

2

6

3

4

5

CA18右前组合灯线束连接器

IP48BCM线束连接器

SO24右后组合灯线束连接器

1 2 3

4 5 6

7 8 9

10 11 12 13

 

 

 

 

 

Inspect the communication between the front ceiling lamp 
and the BCM. 

No 

Repair or replace the harness. 

Yes 

IP48BCMharness connector

 

CA18 right front combination lamp harness 

connector

 

SO24 right rearcombination lamp harness connector

 

1917

 
 

(a)  Disconnect BCM wire harness connector 

IP49. 

(b)  Measure resistance between front dome lamp 

wire harness connector RF12 terminal 2 and 
BCM wire harness connector IP49 terminal 
3. 

Standard Resistance: Less than 1 Ω 

(c) Measure resistance value between front 

celling lamp harness connector RF12 
terminal2 and grounding 

(d)  Measure resistance between front dome lamp 

wire harness connector RF12 terminal 3 and 
grounding. 

Standard Resistance: More than 10 Ω or higher 

Confirm if the resistance conforms to standard 

value. 

NL11-3218b

1

2

3

4

5

6

1

2 3

4 5 6

7

8 9 10

11 12 13 14 15 16 17 18 19 20

IP49BCM线束连接器

RF12前顶灯线束连接器

 

 

 

 

 

Replace the BCM 

(a)  Replace BCM and refer to

 Replacement of BCM in 11.8.8.1

Confirm the completion of repair. 

 

 

The system is normal. 

 

No 

Repair or replace the harness. 

Yes 

Next 

IP49 BCMharness connector

 

RF12 front ceiling lamp harness connector

 

1918

 

 

 

 

 

 

 

 

 

содержание   ..   474  475  476  477  478  479  480  ..