DAF 95XF. Manual - part 767

 

  Index      DAF     DAF 95XF Series - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  765  766  767  768   ..

 

 

DAF 95XF. Manual - part 767

 

 

9

DIAGNOSTICS

Rear axle alignment

3-2

SYMPTOM: AXLE MISALIGNMENT

Possible cause

Remedy

Bent leaf-sprung trailing axle yoke.

Replace the trailing-axle yoke.

Misalignment of the vehicle because the
superstructure is heavier on one side.

Measure the wheel pressure. Distribute the
weight more evenly.

Inadequate alignment of axle suspension.

Check the alignment. Adjust the axle alignment.

Bent chassis.

Measure the chassis.
Straighten the chassis, if possible.

Chassis side members have shifted in relation to
one another.

Measure the chassis.
Straighten the chassis, if possible.
Align the axle.

1

ǹ 200316

9

Contents

CHASSIS

1

CONTENTS

Page

Date

1.

GENERAL

1-1

9701

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . .

1.1

Repairs to the chassis

1-1

9701

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . .

1.2

Drilling in the chassis

1-6

9701

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . .

2

ǹ 9701

9

CHASSIS

Contents

2

2

ǹ 9701

9

General

CHASSIS

1-1

1. GENERAL

1.1 REPAIRS TO THE CHASSIS

-

Any welding, aligning, drilling and
wheelbase alteration activities that are not
described in this workshop manual, or in
any of the latest releases of DAF’s Chassis
Guidelines, must be authorised by DAF.

-

Following chassis repair, the cause of the
chassis damage should be rectified.

Welding
-

Chassis welding may only be carried out by
welders holding a valid EN 287-1 certificate.

-

For welding operations on steel grade
KF 375 chassis, the welding electrode must
meet one of the following standards:
ISO 2560

:

E 515 B24 (H)

DIN 1913
(January 1976)

:

E 5155 B10

EN 499

-

Slag inclusions and other contaminations in
the weld are totally unacceptable.

Note:
Welding on chassis constructed of
high-tensile strength steel grades KF 420,
KF 500 en KF 600 is not recommended.
If, however, you do wish to weld a
high-tensile strength steel chassis, contact
must always first be sought with DAF.
The welding electrode must meet the
DIN 8529 standard:
EY 5066 1.5 NiNoB

2

ǹ 9701

 

 

 

 

 

 

 

Content   ..  765  766  767  768   ..