© 200438 1-3 AGS fault codes AGS DAVIE XD diagnostics manual 14 1.3 EXPLANATORY NOTES TO AGS (BELLOWS VERSION) FAULT CODES Fault code Fault code description with possible cause Symptom 01-33 No pressure build-up detected by the integrated insufficient amount of grease in the reservoir - open connection in the main pipe of the - air in the system - interrupted integrated pressure switch - No grease is supplied to the lubricating - AGS warning on the display is activated 01-34 Pressure build-up detected by the integrated closed integrated pressure switch - No grease is supplied to the lubricating 02-03 Internal short circuit to supply in automatic - Pump remains continuously active - Insufficient grease is supplied to the 02-05 Internal interruption in automatic lubrication pump - No grease is supplied to the lubricating 03-04 Short circuit to earth in AGS warning light due to: short circuit to earth on pin 4 of the ECU - AGS warning is not activated 03-05 Interruption in AGS warning light due to: interruption on pin 4 of the ECU - AGS warning is not activated |